• Keep these instructions in a safe
place and pass them on when gi-
ving the device to a third party.
• This unit is suitable for outdoor
use.
• Please make sure that the con-
nected hosepipe is laid out in such
a way, that it does not become a
tripping hazard.
4. Contents
• Water Animal-repellent
• Sprinkler unit
• Ground spike, 2-parts
• Standard connector for garden hose
• Stopper Cap
• Instruction manual
5. Getting started
The Gardigo Water Animal-repellent, Solar is powered by batte-
ries. The garden hose is connected with a quick snap connector.
Inserting the batteries:
1. You will need two Mignon (AA) batteries.
2. Open the cover of the battery compartment
below the PIR sensor by sliding it downwards.
3. Open the battery compartment by lifting up the latch
4. Insert the batteries. Pay attention to the polarity. The mi-
nus end of the battery always connects to the spring in the
battery compartment.
5. Close the battery compartment
rubber sealing is in the groove and has not been twisted.
6. Slip the cover of the battery compartment back on.
Assembly:
1. Screw the plastic tube to the connector
the device.
2. Screw the metal spit to the plastic tube
3. Screw the quick connector for the garden hose to the metal
spit
.
4. Screw the spraying unit
5. The repellent can now be set up in the garden or near the
pond.
Operation:
To set up the Water Repellent choose a spot that will oversee
the area you want to clear of animals. Make sure to look for a
position where the animals will walk across the sensors view-
ing area rather than walking directly towards the sensor. Make
located
. Make sure that the
at the bottom of
.
to the top of the device.
sure that the view of the sensor is not obstructed by leaves
or foliage and that the surface of the sensor is clean. When
adjusting sensor sensitivity you need to consider what kind of
animal you want to scare away and the distance of detection
(see below). It is possible to adjust the angle and the distance
of the waterspout. Make sure that the sensor has a stable
stand, as the recoil during the waterspout can be quite strong.
Place the ground spit into the ground. If the earth is too hard
we recommend to soften it by soaking it with water. The sen-
sor should not be higher than 1 m above the area that is being
controlled. If you want to place the device in an area that has
no soil, we recommend the use of an umbrella stand.
Note: False alarms can be triggered by objects that are warmer
than the surroundings, by strong water movement, by rapid
temperature changes and by house pets. On very hot days it
may occur that an animal is not detected as the surrounding
temperature is equal to that of the body temperature. This
function is normal for a PIR sensor.
Connect your garden hose to the quick connector on the spike
. Make sure that the hose and all connections are in good
condition and that there is no leakage. Make sure that there is
no sand or other debris is in the garden hose. If you do not want
to use the second outlet in the spike, then close this with the
supplied cap
. You should check the function of the device,
before opening the water tap. Switch the device to position 9
.
Small animals
Medium
animals
Large animals
3 m detection: mode 5 – 7
6 m detection: mode 8 – 9
3 m detection: mode 3 – 4
6 m detection: mode 5 – 6
10 m detection: mode 7 – 9
3 m detection: mode 1 – 3
6 m detection: mode 4 – 6
10 m detection: mode 7 – 9
7