Troubleshooting Procedures (cont.)
Symptoms
"TEMP SENSOR" LED is
3.
ON flashing red, ON solid
green, or ON solid red.
"DATA LINK" LED is ON
4.
flashing red, ON solid
green, or ON solid red.
5.
No steam is being
generated.
6.
There is a continuous
flow of water from the
steam head. (Water flow
during automatic purge
cycle is normal.
Kohler Co.
Probable Causes
A. The room temperature sensor is
disconnected.
B. The room temperature sensor
assembly is damaged.
C. The steam adapter is damaged.
A. The steam adapter is not
properly connected to the media
module.
B. The cable between the steam
adapter and the media module.
is damaged.
C. Bad heating element.
A. The piping is not properly
attached.
B. The steam head is blocked.
A. The water supply is incorrectly
attached to the steam generator.
B. The water feed assembly is
stuck.
C. The solenoid valve is
malfunctioning.
5
Recommended Action
A. Check room temperature sensor for
proper connection.
B. Replace the room temperature
sensor assembly.
C. Replace the steam adapter.
A. Check the steam adapter cable for
proper connection to the media
module.
B1. Check the steam adapter cable for
proper connection to the media
module.
B2. Replace the cable.
B3. Contact customer service at
1-800-585–STEAM (7832).
C. Contact customer service at
1-800-585–STEAM (7832).
A. Reattach the pipes properly.
B. Remove the steam head (after
cooling) and check that the plunger
slides freely in the cap.
A. Connect the water supply to the
proper inlet.
B. Remove and inspect the water feed
assembly in the generator.
C. Remove and replace the solenoid
valve.
1069332-5-A