Technical specification Standard input voltage: 12V AC
Standard input watt: See rating plate on the lamp (max 50W)
This LED-light is suited for most PAR56 standard pool lights. Suits all Pahlén
lighting type 300, both standard and Marine design.
For under water use only.
The pool light should be connected through an isolation transformer 12V 60W alt.
300W. If you have more than one LED light in your pool, make sure all the lights
are installed on the same transformer and switch.
Both types of lights are connected the same way.
If the external cable or cord of the light is damaged, it should be replaced by a
service agent or other qualified person.
Installation
1. Remove the front ring.
2. Remove the existing lamp unit.
3. Dismantle the old light from the lamp unit frame.
4. Mount the replacement bulb. The spacer (pos 8) shall be placed
where the cable meets the cable gland.
5. Connect the cable.
6. Mount the lamp unit to the poolwall.
7. Mount the Marine front ring.
Start-up
Make sure that each light is installed correctly.
Synchronizing multiple lights
1. To synchronize the lights to the same program, turn the lights on,
wait for a few seconds.
2. Turn off the lights and wait for a minimum of 12 seconds, then switch back on.
3. Change the colour/program 2 times. Now they are synchronized.
Once the lights are synchronized, they will stay that way until one of the LED
lights is replaced or one light is switched on separately from the others.
Changing colour/program: Turn the lamps off and quickly back on (max 10 sec. off).
Memorizing the last colour/program:
1. Select the desired colour/program.
2. Turn the lamps off for minimum 12 seconds. The chosen program has now
been memorized.
The red/green/blue light
The LED light PAR56 is a very advanced electronic controlled light based on
LED's in three colours: red, green and blue. Together these three colours can
produce several other colours. With the on/off switch for your pool lights, one of
the 16 pre-programmed light effects can be selected.
The 16 programs of the red/green/blue light:
1
Warm white
Fixed colour warm white
2
Red
Fixed colour red
3
Green
Fixed colour green
4
Blue
Fixed colour blue
5
Green-blue
Fixed colour green/blue
6
Red-green
Fixed colour red/green
7
Blue-red
Fixed colour blue/red
8
Evening sea
Slow change of colour red/blue
9
Evening river
Slow change of colour red/green
10 Riviera
Slow change of colour green/blue
11
White
Fixed colour neutral white
12 Rainbow
Slow change of colour blue/red/green
13 River of colours
Program 12 followed by program 15
14 Disco
Rapid change of colour
15 Four seasons
Slow change of colour red/
16 Party
Rapid change of colour
Exchange LED lamp unit, red/green/blue
Exchange LED lamp unit, white
Lamp unit Marine
Belysningsinsats Marine
Screw M5x20 (2x)
Assembly order LED light unit
Surface treatment
E
1. Mounting frame ring
The tolerance class in accordance with this
part of ISO 2768-1
2. U-list (optional)
3. Lamp
Box 728, SE-194 27 Upplands Väsby, Sweden
Phone +46 8 59411050, Fax +46 8 59086880
4. Bracket
5. Screw M4
7
6. Foot
7. Screw M5
8. Spacer
6
8
Lamp unit Marine
Belysningsinsats Marine
Screw M5x50 (2x)
Surface treatment
E
The tolerance class in accordance with this
part of ISO 2768-1
Box 728, SE-194 27 Upplands Väsby, Sweden
14
Phone +46 8 59411050, Fax +46 8 59086880
ENGLISH
Countersunk screw
M5x10 (6x)
Skruv M5x10 (6x)
Washer (6x)
Låsbricka (6x)
Fästskruv M5x20 (2x)
Front Marine
Front Marine
Designed by:
Assembly drawing no.
Installationsbild
för MA50-09
Pos 8 är bipackad lampan
Countersunk
M5x10 (6x)
M5x10 (6x)
Washer (6x)
Låsbricka (6x)
Fästskruv M5x50 (2x)
Front Marine
Front Marine
Designed by:
Drawn by: Date
ASA 2012-02-07
Assembly drawing no.
Art.no.
Scale
Installationsbild
för MA50-09
Drawing number
Drawn by: Date
Approved by:
ASA 2012-02-07
Art.no.
Scale
Revised by: Date
Drawing number
Rev.no.
M11604
4
3
2
1
5
screw
Approved by:
Revised by: Date
Rev.no.
M11605

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Led 300ca marine

Tabla de contenido