REPAIR AND MAINTENANCE PROCEDURES
TORQUES NECESSARY FOR THE PROPER FUNCTIONING OF THE PUMP
For proper operation of the pump and to prevent accidents which may
damage equipment and in the worst case, people, you must periodically
review the torques of the diaphragms covers and the DIRECTIONAL
VALVE. In the next table are shown the appropriate torques for this
purpose:
CAUTION!: DO NOT OVERTIGHTEN FASTENERS.
DIAPHRAGM MAINTENANCE
Before any intervention: DISCONNECT AIR SUPPLY OF THE PUMP.
IT IS NOT NECESSARY TO REMOVE THE PUMP FROM THE FLUID LINE.
ANTICIPATE A POSSITE LEAKAGE OF FLUID INSIDE THE PUMP.
INSTALLING THE NEW DIAPHRAGMS - ASSEMBLING PROCEDURE
CAUTION: Follow next procedure to ensure the diaphragms are
correctly installed. If not followed diaphragm bead could be
extruded out of its housing with the resulting damage over the
diaphragm bead and thus possible fluid leaks or premature
diaphragm failure.
 Balcrank Corporation - Weaverville - NC · Tel.: 800-747-5300 · www.balcrank.com
Cover and manifolds
TOR-
QUES
Air cap
TF170
Diaphragms
REMOVING THE DIAPHRAGM:
1. Close inlet and discharge fluid valves.
2. Drain the fluid inside the pump.
3. Remove the diaphragm cover screws.
NOTE: To tighten these screws you must use a torque
wrench calibrated to (see torque table in this page).
4. Remove the cover by gently pulling back.
5. Remove the used diaphragms.
CAUTION!
1. Correct assembly of the
diaphragm before the diaphragm
cover assembly.
80 N·m (60 ft.lbs)
15 N·m (11 ft.lbs)
100 N·m (74 ft.lbs)
2. Incorrect assembly of the
diaphragm.
Possible damage when
assembling the diaphragm cover.
R. 06/20 SB 1206
EN
EN
11