INSTALLATION
AIR EXHAUST DISPOSAL
WARNING
• Optional kit is required for remote exhaust.
• Remove the standard muffler in pump part drawing.
• Place 1 1/2" fitting M-M.
• Connect a hose to the new exhaust port and install the muffler at the
end of the hose. Use a hose with the same diameter as the exhaust port
1 1/2" NPT. (If the hose is more than 1.5 m (5 feet), consult your local
distributor or Balcrank Corporation.
• Have a moat, a protective housing, etc. at the end of the hose.

AIR CONNECTION

WARNING: To ensure that the air supply is sufficient to meet the demand of the pump, the diameter of the pipe must be equal to the diameter
of the supply port of the pump. Choose auxiliary air treatment equipment and fittings with sufficient airflow to exceed the air consumption of
the pump. In addition, peripheral air treatment equipment must be installed as close as possible to the pump unit.
The use of a coupler to connect the hoses aids future operation and maintenance tasks.
6
SB 1206 R. 06/20
 Balcrank Corporation - Weaverville - NC · Tel.: 800-747-5300 · www.balcrank.com
REMOTE EXHAUST
1 1/2" NPT