Fuel Conversion Instructions - HeatStar HSRP37GL Instrucciones De Uso Y Manual Del Usuario

Calefactor de exterior para patio
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

FUEL CONVERSION INSTRUCTIONS

WARNING: Before doing all the operations below, it is
necessary to close the manual main shut-off gas valve and to
remove plug from the socket.
1.
Remove the top cover and the side cover (from valve side). Refer
to Figure 15.
2.
Remove the gas connection from the gas valve.
3.
Remove the 3 screws securing the air flange and remove the gas
valve connector. Refer to Figure 17. To remove the screws use the
"10 key".
4.
Once the valve assembly has been removed, replace the NG
nozzle with the LP nozzle using a "13 key". See Figures 22 and 21.
The nozzle is supplied by Heat Star. Verify the orifice drill size in
Table 1.
5.
Reassemble the unit by performing Steps 1-3 in reverse order.
6.
Make the gas connection as indicated in the GAS SUPPLY
INSTALLATION INSTRUCTIONS section.
7.
At the first re-ignition with different gas, adjust the manifold
pressure to the pressure indicated in Table 1 and on the label
applied on the unit. See Figure 10 for valve adjustment.
8.
Replace the NG label with data of manifold pressure and orifice
drill size with the LP label (supplied with the unit).
FIGURE 21
14
Outdoor Patio Heater
Orifice Change
Change orifice to convert
from NG to LP
Operating Instructions and Owner's Manual
FIGURE 22

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Hsrp37mt

Tabla de contenido