Using The Display Programmer; Auto-Learning Of The Travel Stroke; Quick Programming - Key Automation 14A Instrucciones Y Advertencias Para Su Instalación Y Uso

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50
OPEN command, NO contact between OPEN and COM
OPEN
Contact for the opening function
CLOSE command, NO contact between CLOSE and COM
CLOSE
Contact for the closing function
Stepping command, NO contact between SBS and COM
SBS
Open/Stop/Close/Stop command, or as set in the software

4.2 - Using the display programmer

To customise the programmer's language and contrast, proceed
as follows:
OPTIONS
DISPLAY
N.B.: The first time the display is switched on, the user is
prompted to select the language. Press ▲ or ▼ to select the
language required and then confirm with V.
If no language is selected (X key pressed), the control unit
will use the default language (ENGLISH) until the next time it
is switched on.
In normal mode, i.e. when the system is powered up normally
and the display programmer is connected, press X until
the name KEY AUTOMATION appears. This will display the
following status messages:
EVENT
opening
closure
automatic closure
stop during closure
stop during opening
open
closed
programmation
M1 obstacle
M2 obstacle
photo 1!
photo 2!
sensitive edge!
parcial opening
automatic parcial closure
realignment
FLASH/NLS error
ELEC/IND error
Phototest error
Limit switches error!

4.3 - Auto-learning of the travel stroke

The first time the control unit is powered up, an auto-learning
procedure must be carried out to acquire fundamental parameters

QUICK PROGRAMMING

If this programming mode is used, the decelerations will reset to the default values with the same percentage during both opening and
closing.
Follow the chart below with the programmer display.
N.B. If the decelerations are also to be programmed, move straight on to the next table.
SELECT
LANGUAGE
DESCRIPTION
Gate opening
Gate closing
Gate open with timed reclosure active
Gate stopped during closure
Gate stopped during opening
Gate completely open without automatic reclosure
Gate completely closed
during the programming phase
Motor 1 obstacle detected
Motor 2 obstacle detected
Photocell 1 tripped
Photocell 2 tripped
Sensitive edge tripped
Parcial opening in progress
Gate opening to parcial position with timed reclosure activa-
ted
Realignment after a manual release
Night Light System line overload
Electric lock / gate open light line overload
Phototest error detected
Limit switch/mechanical end stop error detected
SCORRI SU
ANNULLARE
SCORRI GIÚ
Il diagramma di flusso completo del programmatore display si
trova al punto 6.3 a pag. 15.
KEY TO MAIN CONTROL
FLASHING LIGHT AND LEDS
2 quick flashes + pause + 1 flash
4 quick flashes + pause, 3 times
4 quick flashes + pause, 3 times
2 quick flashes + pause, 3 times
2 quick flashes + pause, 3 times
5 quick flashes + pause, 3 times
6 quick flashes + pause, 3 times
6 quick flashes + pause, 3 times
3 quick flashes + pause, 3 times
8 quick flashes + pause, 3 times
such as the travel stroke length and deceleration points.
EN
CONFERMARE
25

Publicidad

Tabla de contenido
loading

Tabla de contenido