6 - FURTHER DETAILS
6.1 - Customising the system - Advanced settings
If necessary, users may select the ADVANCED SETTINGS, which
allow modification of the control unit's advanced parameters.
Proceed as follows:
14A
PARAMETERS
1
PHOTO 1
2
PHOTO 2
3
PHOTOTEST
4
EDGE TYPE
5
SAFETY EDGE
PARCIAL
6
OPENING LENGHT
AUTOMATIC
7
CLOSING FROM
PARCIAL OPEN
8
FLASH LIGHT
9
PRE-FLASHING
COURTESY LIGHT
10
START
COURTESY LIGHT
11
TIME
LIGHT
INTENSIVITY
12
AT END OF
MOVEMENT
13
STOP BUTTON
30
ADVANCED
SETTINGS
DESCRIPTION
Use of PHOTO1 when starting from closed
0 = PHOTO 1 deactivated
1 = PHOTO1 is checked
2 = the gate starts even with PHOTO1 activated
Use of PHOTO2
0 = PHOTO 2 deactivated
1 = enabled during both opening and closing
OP/CL
2 =only enabled during opening OP
Photo-device test
0 = off
1 = PHOTO1 on
2 = PHOTO2 on
3 = PHOTO1 and PHOTO2 on
Sensitive edge type
0 = off
1 = 8k2 sensitive edge
2 = NC contact
3 = double sensitive edge 8k2 in parallel
Sensitive edge tripping mode
0= only tripped during closure with direction
reversal
1 = stops the automation (during both opening
and closure) and retreats from the obstacle
(travels short distance in opposite direction)
Parcial opening
Time for automatic closure from parcial opening
(0=off)
1 to 900 Seconds of delay before automatic
closure from parcial opening
Flashing light output setup
0 = Fix
1 = Flashing
Pre-flashing time (0 = off)
Courtesy light setup
0 = ON at end of operation for courtesy light
time
1 = ON if gate not closed + courtesy light
duration time at end of operation
2 = ON if courtesy light timer has not gone out
since start of operation
Courtesy light duration time (0 = off)
0 = light off after operation
5 = maximum brightness with motor stopped
0 = NC stop button not connected
1 = NC stop button connected
CAUTION: the parameters may vary with respect to those in the table
below, depending on the motor to be installed.
DEFAULT
MIN.
2
1
0
1
0
50
0
1
0
0
30
2
1
MAX.
UNIT
0
2
0
2
0
3
0
3
0
1
% (step
30
100
of 1)
0
900
s
0
1
0
20
s
0
2
0
900
s
0
5
0
1