Descargar Imprimir esta página

JUNO JCLR6 Retrofit Trim Serie Instrucciones De Instalación página 2

Publicidad

Idiomas disponibles

Idiomas disponibles

Installation
When the rough-in section is modified, the loose warning label supplied with this retrofit kit must be affixed to the luminaire in a location visible
after installation. Retrofit kit is voltage specific. Verify proper voltage before installation.
Electrical Connection
Step 1. Turn off electricity at the fuse or
circuit breaker box.
Step 2. Remove existing trim section and
housing (if applicable) to gain access to
the rough-in section junction box. Remove
junction box access cover.
Step 3. Disconnect all primary input wires
leading from input supply to the ballast or
socket.
Step 4. Install the supplied trim conduit whip
into the junction box via knockout using
supplied ½" trade size fitting.
Note: Retrofit conduit whip assembly is
provided with quick disconnect connector
located in LED driver junction box.
Connector can be disconnected to separate
reflector from supply wire connection.
This allows for easy installation of supply
wire connection to retrofit without reflector
interference. (Refer to Figure 4).
Step 5. Connect supply wires to the retrofit
trim wires (Refer to Figure 3).
Step 6. Make certain rough-in section
junction box is grounded. Reinstall junction
box cover.
Dedicated 120 Volt
J-Box Wiring (1)
Black
Hot
White
Neutral
Green
Ground
To LED
Driver
Quick Disconnect Connector
(To LED/Reflector)
LED Driver
Junction Box
Figure 4
Friction Clip "A"
(JCLR6S Aperture Inside Diameter: 6" - 6 1/4")
(JCLR6L Aperture Inside Diameter: 6 5/8" - 6 14/16")
(JCLR8S Aperture Inside Diameter: 7 13/16" - 8 1/16")
(JCLR8L Aperture Inside Diameter: 8 5/8" - 8 7/8")
WARRANTY
Five-year limited warranty. Complete warranty terms located at:
www.acuitybrands.com/CustomerResources/Terms_and_conditions.aspx
Product Services Phone (888) 387-2212
1300 South Wolf Road • Des Plaines, IL 60018 • Phone 800-323-5068 • www.junolightinggroup.com
INSTALLATION INSTRUCTIONS
For JCLR6 and JCLR8 Retrofit Trim Series
Reflector Installation
Note: Rough-in section ring must be present
to utilize provided friction clips.
Step 1. Determine which friction clip to
utilize. Two styles of mounting friction clips
("A" & "B", 3 each) have been provided for
different retrofit aperture ranges. This is to
ensure best fixture retention when installing
reflector trim assembly. When utilizing
provided mounting friction clips, please refer
to Figure 5 for proper friction clip aperture
inside diameter range. Aperture inside
diameter can be determined by measuring
rough-in section as shown in Figure 2 on
previous page.
Step 2. Install each clip along rough-in
section ring (120° apart) by pushing them
upward on the edge of the rough-in section
ring (See Figure 6 & Detail A).
Note: Existing Reflector retainer clips from
old reflector/trim assembly may need to be
removed or bent back to allow proper LED
retrofit reflector installation.
Universal Voltage 120-277 Volt
J-Box Wiring (U)
Black
White
Green
To LED
Driver
Violet
Gray
Figure 3
Bend
Friction Clip "B"
(JCLR6S Aperture Inside Diameter: 6 1/4" - 6 1/2")
(JCLR6L Aperture Inside Diameter: 6 14/16" - 7 1/8")
(JCLR8S Aperture Inside Diameter: 8 1/16" - 8 5/16")
(JCLR8L Aperture Inside Diameter: 8 7/8" - 9 1/8")
Figure 5
Step 3. After friction clip installation,
the reflector trim assembly can now be
installed. Reconnect the conduit whip quick
disconnect connector, if utilized, and close
LED driver junction box. Place LED driver
junction box thru the ceiling cut-out and
allow it to rest on the ceiling.
Step 4. Push reflector trim assembly
through rough-in section hole and make
sure mounting friction clips engage against
reflector.
Step 5. Restore power after installation of
fixture is completed
Driver Replacement
Driver replacement must be performed by
a qualified electrician. Remove reflector
trim assembly from rough-in section and
disconnect driver junction box connector
(Figure 4). Remove driver whip assembly
from rough-in section junction box. Order
replacement part number as identified on
the driver.
Hot
Neutral
Ground
To LED
Driver
(+) Positive
(-) Negative
Detail A
Rough-In
Section Ring
© 2016 Acuity Brands Lighting, Inc.
Dedicated 347 Volt
J-Box Wiring (3)
Black
Hot
White
Neutral
Green
Ground
Violet
(+) Positive
Gray
(-) Negative
Rough-In Section
Junction Box
See Detail A
Friction Clips (3X)
120˚ Apart
Figure 6
Rev 8/16
P5520
pg 2 of 2

Publicidad

loading

Este manual también es adecuado para:

Jclr8 retrofit trim serieJclr6l-24-827k3-whJclr6l-20-940k1-hzJclr6s-20-940k1-hzJclr8s-24-840k1-whJclr6l-18-840k1-hz ... Mostrar todo