Thermostat Schedule; Troubleshooting; Homeowner Help Line - Emerson 80 Serie Instrucciones De Instalación Y Funcionamiento

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

THERMOSTAT SCHEDULE

Energy Saving Factory Schedule
This thermostat is programmed with the energy saving settings shown in the table below for
all days of the week.
Wake
Leave
Heating Schedule
6:00 AM - 70°F
8:00 AM - 62°F
Cooling Schedule
6:00 AM - 75°F
8:00 AM - 83°F
Note: Thermostat can be programmed on or off the subbase
Modify the Heating Schedule
1.) Slide the system switch to Heat
2.) Press Menu
3.) Press Next to enter the schedule
4.) The time icons will flash – use
or
5.) Press Next – the set point icons will flash – use
current period
6.) Continue to press Next to advance through all periods (Wake, Leave, Return, Sleep)
for all days of the week.
Note: Press Back to return to the previous setting. Once all days of the week have been pro-
grammed the thermostat will display End. Press Exit at any time to save changes and
return to home screen.
Modify the Cooling Schedule
1.) Slide the system switch to Cool
2.) Repeat steps 2-6 from the heating schedule

TROUBLESHOOTING

Symptom
Possible Cause
1.) Blown fuse or tripped circuit
breaker
2.) Furnace power switch to OFF
No Heat/
No Cool/
3.) Furnace blower compartment
No Fan
door panel loose or not properly
(common problem)
installed
4.) Loose connection to thermostat
or system
1.) System Switch not set to Heat
2.) Loose connection to thermostat
or system
3.) Heating System requires
service or thermostat requires
replacement
No Heat
(Troubleshooting continued on next page)
7
Return
Sleep
5:00 PM - 70°F
10:00 PM - 62°F
5:00 PM - 75°F
10:00 PM - 78°F
to set the time for the start of a period
or
to set the temperature for the
Corrective Action
1.) Replace fuse or reset breaker
2.) Turn switch to ON
3.) Replace door panel in proper position to
engage safety interlock or door switch
4.) Tighten Connections
Verify thermostat and system wires are securely
attached.
Diagnostic: Set System Switch to Heat and raise
the setpoint above room temperature. Within five
minutes the thermostat should make a soft click
sound and "Heat On" should appear on display.
This sound indicates the thermostat is operating
properly. If the thermostat does not click, try the
reset operation listed below. If the thermostat
does not click after being reset, contact your
heating and cooling service person or place of
purchase for a replacement. If the thermostat
clicks, contact the furnace manufacturer or a
service person to verify the heating system is
operating correctly.
TROUBLESHOOTING (C0ntinued)
Symptom
Possible Cause
1.) System Switch not set to Cool
2.) Loose connection to thermostat
or system
3.) Cooling System requires
service or thermostat requires
No Cool
replacement
Heat, Cool or Fan
Possible short in wiring, thermostat,
Runs Constantly
heat, cool or fan system
Thermostat
Display &
Thermostat display requires
Thermometer
adjustment
Disagree
Furnace (Air
Conditioner)
The location of the thermostat and/
Cycles Too Fast or
or the size of the Heating System
Slow (narrow or
may be influencing the cycle rate
wide temperature
swing)
1.) Heating system is not able to heat
the space to within 10 degrees of
the setpoint within 2 hours
2.) Cooling system is not able to cool
the space to within 10 degrees of
the setpoint within 2 hours
"Call for Service"
3.) If "--" is displayed for the Room
icon appears on
Temperature, a replacement
displayed
thermostat is needed
4.) None of the buttons operate on
the thermostat
5.) If "Call for Service" is flashing,
compressor self diagnostic is
detecting an issue with the
outdoor unit
Resetting the Thermostat or Thermostat Settings
If the thermostat has good batteries, but has a blank display or does not respond to key
presses, the thermostat should be reset by removing the batteries for 2 minutes. This reset
will not change the menu settings or program. If the condition persists after reinstalling the
batteries, replace the thermostat.
To conveniently reset only the schedule and user settings back to factory defaults, press Menu
and Backlight buttons at the same time and hold until the display goes blank and resets.

HOMEOWNER HELP LINE: 1-800-284-2925

White-Rodgers is a business
of Emerson Electric Co.
The Emerson logo is a
trademark and service mark
www.white-rodgers.com
of Emerson Electric Co.
www.emersonclimate.com
Corrective Action
Verify thermostat and system wires are securely
attached.
Diagnostic: Set System Switch to Cool and
lower setpoint below room temperature. Same
procedures as diagnostic for "No Heat" condition
except set the thermostat to Cool and lower the
setpoint below the room temperature. There may
be up to a five minute delay before the thermostat
clicks in Cooling if the compressor lock-out option
is selected in the installer menu. (see INSTALLER
MENU, item 50)
Check each wire connection to verify they are not
shorted or touching other wires. Try resetting the
thermostat. If the condition persists contact your
HVAC service person.
Display can be adjusted +/-5°. See User Menu
item 04
Digital thermostats provide precise control and
cycle faster than older mechanical models. The
system turns on and off more frequently, but runs
for a shorter time. If you would like to increase
cycle time, choose SLO for slow cycle in the
Installer menu. (Reference menu items 30 & 35) If
an acceptable cycle rate is not achieved, contact
your HVAC service person.
1.) See corrective action for "No Heat"
2.) See corrective action for "No Cool"
3.) Replace thermostat
4.) Make sure keypad lockout is not turned on
(denoted by icon)
5.) Contact a service person to verify the
equipment is operating correctly