Installation, cont'd.
Hose Barb Planning
Regardless of installation selection, plan to minimize stress points on the hose.
RECOMMENDATION: Plumb the hose barb AT OR NEAR BOTTOM of the compartment with the hose barb pointing AWAY
NOTICE
from the RV coach.
o
90
Hose Barb - Plumbed from Bottom,
Side, or Back
Electrical Planning
2A
K4
Ref.
Description
K1
Macerator Pump
K3
Macerator Switch
K4
35A Fuse/Breaker
2A
Battery
2B
Relay
2C
Over-Temperature Switch (90°C) normally closed
2D
Ground
Wire Gauge Size Chart
If Wire Gauge for distance from
source* is:
12 VOLTS - Install
* Distance measured assumes power
and ground wires
Wire Size
Fig. 3
represents recommended wiring confi guration. Other wiring confi gurations are possible based on your installation.
Wiring confi guration MUST include internal over-temperature switch and relay for protection of pump.
Pump requires a 12-VDC/35 AMP dedicated circuit with 35 AMP breaker or fuse between main bus or battery.
Wire size is dependent on distance between pump and power source. Actual wire sizes should be calculated according to instal-
lation.
97572 Rev. B (07/10/2017)
Fig. 2
Switch Box Assembly
2B
85
86
0-18 feet
19-32 Feet
(Included)
10 Gauge
8 Gauge
Fig. 3
4
K3
K1
The positive and negative wires should be braided to
NOTICE
prevent radio interference during operation.
While the pump is turned on, verify electrical system
NOTICE
AVISO
AVIS
!
CAUTION
by measuring voltage at motor; (must be 12V).
Improper installation may cause damage to motor or
decrease pump effi ciency.
33-50 feet
6 Gauge
Pump Assembly
2C
18G BLU
18G BLU
Included in product
Circuit Breaker
35 amp
®
SANICON
Turbo - Model 500
2D
2D