Table 1-2. LCD Status Messages (continued)
Line 1
Line 2
Message
Message
RPM FAN PS BLANK Power supply fan RPM is out
E0412
RPM FAN n
E0412
FAN REDUNDANCY
LOST
E0780
PROC # CONFIG
ERR
E0780
PROC # DISABLED
PROC n PRESENCE
E0780
PROC n IERR
E07F0
8
Information Update
Causes
of acceptable range.
Specified cooling fan is faulty,
improperly installed, or missing.
The specified processor has a
configuration error.
The specified processor is
disabled.
Microprocessor is not installed
in socket n.
Faulty or improperly installed
microprocessor.
Corrective Actions
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide.
Install a microprocessor in socket
n. See "Installing a Processor"
in your Installation
and Troubleshooting Guide.
See "Troubleshooting the
Microprocessors" in your
Installation and Troubleshooting
Guide.