Dell PowerEdge 6850 Actualización De Información página 11

Ocultar thumbs Ver también para PowerEdge 6850:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 102
Table 1-2. LCD Status Messages (continued)
Line 1
Line 2
Message
Message
PROC n THERMTRIP Specified microprocessor is out of
E07FA
PS n MISSING
E0876
PS n STATUS
PS n PREDICTIVE
E0876
PS n AC LOST
E0876
PS n AC RANGE
E0876
PS # AC OUT OF
RANGE - APPLY
200-240V
Causes
acceptable temperature range and
has halted operation.
No power available from the
specified power supply; specified
power supply is improperly
installed or faulty.
Power supply voltage is out of
acceptable range; specified power
supply is improperly installed or
faulty.
Power source for specified power
supply is unavailable, or out of
acceptable range.
The AC power to the specified
power supply is out of operating
range.
Corrective Actions
See "Troubleshooting System
Cooling Problems" in your
Installation and Troubleshooting
Guide. If the problem persists,
ensure that the microprocessor
heat sinks are properly installed.
See "Removing a Processor" in
your Installation
and Troubleshooting Guide.
NOTE:
The LCD continues to
display this message until the
system's power cord is
disconnected and reconnected to
the AC power source, or the SEL is
cleared using either Server
Assistant or the BMC Management
Utility. See the Dell OpenManage
Baseboard Management
Controller User's Guide for
information about these utilities.
See "Troubleshooting Power
Supplies" in your Installation
and Troubleshooting Guide.
See "Troubleshooting Redundant
Power Supplies" in your
Installation and Troubleshooting
Guide.
Check the AC power source
for the specified power supply.
Check the power source and
verify that it is supplying 215-
220V power. If the problem
persists, see "Getting Help"
in your Installation
and Troubleshooting Guide.
Information Update
9

Publicidad

Tabla de contenido
loading

Tabla de contenido