Operating Faults And Reset; Temporary Shutdown; Preparing For Extended Periods Of Disuse; Parameters Menu - Beretta Idrabagno Lx 11Serie Manual Del Instalador Y Usuario

Calentador de cámara estanca
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 41

4.5 Operating faults and reset

In the event of a fault, the displays summarised and described in the table
are shown.
Error type
Limit thermostat alarm
Air pressure switch fault
Burner thermostat alarm
Air pressure switch alarm
ACF alarm lockout module
ACF electronics fault alarm
Overtemperature fault
Domestic hot water NTC
Fault
Input NTC Fault
In the event of a transitory fault the appliance independently attempts a
reset of operations.
In the event of a permanent fault it is necessary to reset the normal oper-
This operation can be repeated a maximum of 2 times. If the problem is
not resolved, request help from the Technical Assistance Centre.
b
The system provides for the alarms to remain operational even in
the ON-OFF/RESET state. In this state they are not displayed how-
ever. In the event a lockout occurs when the function is OFF, to
reset it the water heater must be set to ON and then to OFF again.

4.6 Temporary shutdown

In case of temporary absences for weekends, short trips, etc.:
-
- turn the main system switch to "off".
A
Transitory
Error code
02
Transitory
03
04
03
01
01
Transitory
11
88°C
Transitory
06
Transitory
08
Fig. 12
Fig. 13

4.7 Preparing for extended periods of disuse

If the appliance is not going to be used for a long period of time, the fol-
lowing operations should be carried out:
-
Icons
- switch the boiler OFF at the mains power switch
- shut-off the system's fuel and water taps.
b
Empty the system if there is a risk of freezing.

4.8 Parameters menu

The two central segments of the digits blink and together with them some
displayed icons.
Use the "+" or "-" key to select the wrench icon (
central segments switch off.
Press the "+" key to increase the numeric value until you reach the value
of the password.
B
MENU.
When accessing the technical menu the number "2" is displayed. Press-
ing the "+" or "-" key it is possible to select the successive parameter:
2
Burner output
4
Gas Type
Flow Indicator Type
5
Domestic hot water start wait time
6
Domestic hot water circuit maximum setpoint
11
20
Induced draught protection function
40
Domestic hot water thermostat operation
Displaying domestic hot water input temperature
41
42
Exiting the menu
rt
rs
Resetting factory settings
If no action is taken, once 2 minutes have passed the appliance exits the
menu and returns to the normal operation screen.
psw (*)
The user can in no way access the TECHNICAL
ENGLISH
Fig. 14
Fig. 15
-
23

Hide quick links:

Publicidad

Tabla de contenido
loading

Tabla de contenido