• Make sure you have enabled the extended Menu 3
(as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L3;
• Press the SET key;
• LED L3 becomes steady on and programming will be completed.
If you wish to enable the function at the power level set by the FORCE
trimmer, repeat the above mention programming, by pressing SELECT twice
(obtaining fast flashing of LED L3 instead of once) and then press SET.
Repeat the procedure if you wish to restore the previous configuration.
8.4.4. LED L4 - SLAM LOCK: (in closing phase):
The control unit is supplied by factory with the Slam lock function disabled.
This function consists in adding, in the presence of a deceleration stage
during closing, a stroke lasting 1 second at the maximum power or at the
power selected with the "FORCE" trimmer, in such a way as to ensure
positive engagement of the gate lock, if installed. If you wish to enable the
Slam Lock function at maximum power, proceed as follows:
• Make sure you have enabled the extended Menu 3
(as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L4;
• LED L4 becomes steady on and programming will be completed.
If you wish to enable the function at the power level set by the FORCE
trimmer, repeat the above mention programming, by pressing SELECT
twice (obtaining fast flashing of LED L4 instead of once) and then press SET.
Repeat the procedure if you wish to restore the previous configuration.
8.4.5. LED L5 - ELECTRICK LOCK ACTIVATED BY DISABLED PED. BUTTON:
The control unit is factory set with the function for electric lock activation
via the Pedestrian command disabled. The function for electric lock
activation with the Pedestrian command is used when, for example, the
application consists of a sliding gate with a pedestrian gate alongside.
With this function enabled the sliding gate can be opened both using
commands from the P/P Pushbutton and the remotes, and via the PED
commands from the pedestrian gate by activating the electric lock.
To enable this function proceed as follows:
• Make sure you have enabled the extended Menu 3
(as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L5;
• LED L5 becomes steady on and programming will be completed.
Repeat the procedure if you wish to restore the previous configuration.
8.4.6. LED L6 - FLASHING LIGHT / INDICATOR LIGHT / COURTESY LIGHT:
By activating this function it is possible to change the indicator light (it does
not flash during the pause), while the flashing output becomes a courtesy
light. To enable this function proceed as follows:
• Make sure you have enabled the extended Menu 3
(as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L6;
• LED L6 becomes steady on and programming will be completed.
If you wish to enable the second variation, repeat the operation described
above, pressing the SELECT key twice (obtaining the fast flashing of the
LED L6 instead of once) and then press SET (the LED does not light up).
Repeat the procedure if you wish to restore the previous configuration.
Courtesy Light Operation: The 24 ~ 4W max. Courtesy Light output will
switch on for 3 minutes whenever an opening command is transmitted.
8.4.7. LED L7 - PRE-FLASH/FLASH IN PAUSE:
The control unit is supplied by the factory with the Pre-flashing and Flashing
during Pause (3 sec. pre-flash before closing phase) both disabled.
Pre-flashing operation: The 24V flasher output will always be
activated 3 seconds before the closing manoeuvre.
If you wish to enable the Preflashing function, proceed as follows:
• Make sure you have enabled the extended Menu 3
(as shown by the alternate flashing 1 1 1 0 1 1 1 0 of LEV LED);
• By the key SELECT, position yourself on the blinking LED L7;
• LED L7 becomes steady on and programming will be completed.
Flashing operation during the Pause: The 230 Vac and 24V flashing light
output will remain active if the pause time is previously programmed. If
you wish to enable this function, repeat the operation described above,
pressing the SELECT key twice (obtaining the fast flashing of the L7 LED)
and then press SET. The L7 LED will remain on steady.
Repeat the procedure if you wish to restore the previous configuration.
9 RESET
If it is necessary to restore the control unit to the factory configuration,
press the SELECT and SET keys simultaneously for about 5 seconds;
this will cause all the RED indicator LEDs to light simultaneously followed
immediately by the control unit switching off.
10 DIAGNOSTICS
Photocell Test:
The control unit is prearranged for connection of safety devices in compliance
with standard EN 12453 point 5.1.1.6. At each operating cycle a functional test
of the connected photocell is performed. In the case of an open circuit and/or
malfunctioning of the photocell, the control unit does not enable movement of
the gate and visually signals the test failed condition by causing all the indicator
LEDs to blink simultaneously. As soon as correct operation of the photocell
is restored, the control unit is ready for normal use. This operating mode
guarantees failure mode monitoring in compliance with EN 954-1 Category 2.
Commands input test:
In correspondence with each low voltage command input, the control unit is equipped
with an indicator LED so that the status of the input can be checked at a glance.
Operating logic: LED on input closed, LED off input open.
Flashing of all the LEDs of the MAIN MENU:
• obstacle for current measurement;
• obstacle for encoders;
• radio control already programmed;
• non-compliance with the rule of the first stored remote control;
Black-out test:
After programming the motor time, simulate a Black-Out and check that the leaves
perform a complete opening maneuver and a complete closing maneuver."
11 WARRANTY
11.1 - In business relationships or in case of products sold for professional
use, this warranty is limited to the repair or replacement of product parts that
FRATELLI COMUNELLO SPA acknowledges as defective, through equivalent
re-manufactured Products (the "Conventional Warranty"); the warranty does not
include the costs necessary for repairing or replacing the material (e.g. labour costs,
rental of equipment etc).
11.2 - The provisions contained in articles 1490 to 1495 of the Italian Civil Code
shall not apply.
11.3 - FRATELLI COMUNELLO SPA warrants the proper operation of the products
within the limits indicated in 1 above. Unless otherwise agreed, the validity of the
Conventional Warranty is 24 (twenty-four) months from the production date, which
can be found on the products. The Warranty shall be effective and binding on
COMUNELLO only if the product has been correctly installed and maintained in
accordance with the installation and safety rules set out in the documentation
provided by COMUNELLO or otherwise available on the website http://www.
comunello.com/corporate/general_conditions_sales/
11.4 - The warranty does not cover: failures or damage caused by transport;
failures or damage caused by defects in the electrical system of the buyer and/or
by carelessness, negligence, inadequate or abnormal use of such system; failure or
damage due to tampering carried out by unauthorized personnel or due to incorrect
use / installation (in this regard, system maintenance at least every six months is
recommended) or the use of non-original spare parts; defects caused by chemical
agents and/or atmospheric phenomena.
The warranty does not cover the cost of consumables; in any event, COMUNELLO
shall be entitled to a consideration for the work performed at the Customer, where
such work proves useless as the warranty did not apply or because the customer
had used the Comunello product in a negligent, reckless or incompetent manner,
such that the proper use of the product could have avoided the work.
11.5 - Implementation terms: unless otherwise agreed, the right to the Conventional
Warranty is exercised by showing a copy of the purchase document (invoice) to
COMUNELLO. Any defect must be notified to COMUNELLO within the time limit of
thirty (30) days from detection of the defect.
The action must be exercised within the limitation period of 6 (six) months from
detection of the defect. The Product parts for which the Customer requests
application of the Conventional Warranty must be returned by the Customer to
FRATELLI COMUNELLO SPA, Via Cassola 64, 36027 Rosà (VI) Italy.
11.6 - The Customer cannot claim compensation for indirect damage, loss of profits,
loss of production and in any case it cannot claim compensation for an amount that
exceeds the value of the supplied components or products. All transport costs
for Products that have been repaired or to be repaired, although covered by the
Conventional Warranty, shall be charged to the Customer.
11.7 - No external work carried out by Comunello technical staff is covered by the
Conventional Warranty.
11.8 - Specific amendments to the Conventional Warranty conditions described
herein can be defined by the parties in their commercial contracts.
11.9 - The Court of Vicenza (Italy) shall be the place of jurisdiction for any dispute
which will be settled according to the Italian laws.