In order to ensure electromagnetic compliance, only use the power cable and the keypad included in delivery.
Only use connector cables less than 3 m in length. Use the keypad with MACSQuant® Tyto® Cell Sorter models
only.
Ensure that the main switch as well as the plug of the power cable are easily accessible and located as close to
the operator of the instrument as possible. If it is necessary to disconnect the power supply, unplug the cable
from the power outlet.
The instrument should only be operated from a power source that meets the specifications mentioned on the
product´s electrical ratings label. If you have questions about the type of power source to use, contact your
authorized Miltenyi Biotec service provider or local power company.
Do not use extension cords or power strips. Do not overload an electrical outlet.
Optical radiation hazards
The MACSQuant® Tyto® Cell Sorter is classified as a Class 1 M laser product per standard IEC 60825-1:2014. The
MACSQuant Tyto® Cell Sorter is equipped with three Continous-Wave Lasers (laser class 3B). These lasers are
secured by a protective housing and by an interlock.
controls or adjustments or performance of procedures other than those specified herein may
result in hazardous radiation exposure .
The instrument is equipped with a 2D Code Reader. The light-emitting diodes (LEDs) emit invisible light for
illuminating the reading area. According to the international standard IEC 62471, this lamp system is in the
Exempt risk group.
Do not look directly at laser or LED radiation or reflected laser or LED radiation from a mirrored
surface. Otherwise, eye injury may result. Do not direct the laser beam at others.
Radiation of disassembled units may lead to eye injuries.
installed laser or LED radiation sources or their mounting rackets. The laser or LED radiation
sources do not automatically stop emitting when disassembled.
Internal Laser 1
Internal Laser 2
Internal Laser 3
Table 1.1: Laser output power, pulse time, and wavelength.
Chemical and biological hazards
Depending on the biological material used, contamination infection may lead to severe personal injury or
death. All clinical samples must be considered potentially infectious.
If biohazardous material is or has been used, the operator must choose and wear personal
safety equipment as indicated in the warnings and precautions for the particular substance.
The above safety precaution also accounts for any hazardous chemical, including toxic or
corrosive chemicals, acidic or radioactive substances that may be present in the sample.
8
Do not remove the protective housing. Use of
Do not disassemble, modify, or remove the

Output power

Pulse time
100 mW
Continuous
100 mW
Continuous
100 mW
Continuous
Wavelength
638 nm
488 nm
405 nm