INSTALLATION
MANUAL
R410A SPLIT SERIES
MODELS
ATXN25LV1B
ATXN35LV1B
ATXN50LV1B
ATXN60LV1B
Серия R410A с раздельной установкой
ARXN25LV1B
ARXN35LV1B
ARXN50LV1B
ARXN60LV1B
Installation Manual
R410A Split Series
Manuale d'installazione
Serie Multiambienti R410A
Installationsanleitung
Split-Baureihe R410A
Manual de instalación
Serie Split R410A
Manuel d'installation
Série split R410A
Montaj kýlavuzlarý
R410A Split serisi
Руководство по монтажу
IM-5WMYJ-1111(3)-DAIKIN SIESTA
Part Number: R08019037191C
E ngl is h
I tali ano
D e utsch
E s pañol
Fr ança i s
Tür k ç e
Р усский

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Daikin Siesta ATXN25LV1B

  • Página 1 Fr ança i s Série split R410A Montaj kýlavuzlarý Tür k ç e R410A Split serisi Руководство по монтажу Р усский Серия R410A с раздельной установкой MODELS ATXN25LV1B ARXN25LV1B ATXN35LV1B ARXN35LV1B ATXN50LV1B ARXN50LV1B ATXN60LV1B ARXN60LV1B IM-5WMYJ-1111(3)-DAIKIN SIESTA Part Number: R08019037191C...
  • Página 3: Outline And Dimensions

    OUTLINE AND DIMENSIONS Indoor Unit THE MARK SHOWS PIPING DIRECTION REAR REAR LEFT RIGHT TOP VIEW NAME PLATE SIGNAL RECEIVER TERMINAL BLOCK WITH EARTH INDOOR UNIT TERMINAL ON/OFF SWITCH SIDE VIEW BOTTOM BOTTOM ROOM TEMPERATURE THERMISTOR (INSIDE) LOUVER FRONT GRILLE FIXED SCREWS (INSIDE) FRONT VIEW Use tape measure as shown.
  • Página 4 © Recommended mounting plate retention spots (7 spots in all) Through the wall hole Ø 65mm Liquid pipe end Gas pipe end Drain hose position INSTALLATION PLATE ATXN50/60LV1B All dimensions are in mm Dimension Model ATXN25/35LV1B ATXN50/60LV1B 1065 Outdoor Unit [ARXN25/35LV1B] All dimensions are in mm Dimension Model...
  • Página 5 Outdoor Unit [ARXN50/60LV1B] All dimensions are in mm Dimension Model ARXN50/60LV1B Dimension Model ARXN50/60LV1B...
  • Página 6: Safety Precautions

    INSTALLATION MANUAL This manual provides the procedures of installation to ensure a safe and good standard of operation for the air conditioner unit. Special adjustment may be necessary to suit local requirement. Before using your air conditioner, please read this instruction manual carefully and keep it for future reference. This appliance is intended to be used by expert or trained users in shops, in light industry and on farms, or for commercial use by lay persons.
  • Página 7 IMPORTANT Important information regarding the refrigerant used This product contains fluorinated greenhouse gases covered by the Kyoto Protocol. Do not vent gases into the atmosphere. Refrigerant type: R410A value: 1975 GWP = Global Warming Potential Please fill in with indelible ink, 1 the factory refrigerant charge of the product, „...
  • Página 8: Installation Diagram

    INSTALLATION DIAGRAM Indoor Unit Caulk pipe hole gap 30mm or more from ceiling Cut thermal insulation pipe to an with putty. appropriate length and wrap it with tape, making sure that no gap is left Front panel in the insulation pipe’s cut line. Wrap the insulation pipe with the finishing tape 50mm or more from walls...
  • Página 9 Drain work. (Heat Pump Unit Only) 1) Use drain plug for drainage. Drain water hole 2) If the drain port is covered by a mounting base or floor surface, place additional foot bases of at least 30mm in height under the outdoor unit’s feet.
  • Página 10: Installation Of The Indoor Unit

    INSTALLATION OF THE INDOOR UNIT The indoor unit must be installed in such a way so as to prevent The refrigerant piping can be routed to the unit in a number short circuit of the cool discharged air with the hot return air. of ways (left or right from the back of the unit), by using the Please follow the installation clearance shown in the figure.
  • Página 11 Mounting Installation Plate Hole with cone drill Ensure that the wall is strong enough to withstand the weight Inside Outside of the unit. Otherwise, it is necessary to reinforce the wall Wall embedded pipe Caulking (Field supply) with plates, beams or pillars. Use the level gauge for horizontal mounting, and fix it with 5 suitable screws for ATXN25/35LV1B and 7 suitable screws Ø...
  • Página 12: Refrigerant Piping

    REFRIGERANT PIPING Allowable Piping Length If the pipe is too long, both the capacity and reliability of the unit will drop. As the number of bends increases, resistance to the flow of refrigerant system increases, thus lowering cooling capacity. As a result, the compressor may become defective. Always choose the shortest path and follow the recommendations as tabulated below: Indoor unit Outdoor Unit...
  • Página 13 REFRIGERANT PIPING Piping Works And Flaring Technique Figure I • Do not use contaminated or damaged copper tubing. If Cutting Copper Tube any piping, evaporator or condenser had been exposed or 1/4t had been opened for 15 seconds or more, the system must be vacuumed.
  • Página 14: Electrical Wiring Connection

    ELECTRICAL WIRING CONNECTION IMPORTANT : * The figures shown in the table are for information purpose only. They should be checked and selected to comply with the local/national codes of regulations. This is also subject to the type of installation and conductors used.
  • Página 15: Vacuuming And Charging

    SPECIAL PRECAUTIONS WHEN DEALING WITH R410A UNIT R410A is a new HFC refrigerant which does not damage the • Use tools and materials exclusively for refrigerant R410A. ozone layer. The working pressure of this new refrigerant is Tools exclusively for R410A are manifold valve, charging 1.6 times higher than conventional refrigerant (R22), thus hose, pressure gauge, gas leak detector, flare tools, torque proper installation/servicing is essential.
  • Página 16: Indicator Lights

    INDICATOR LIGHTS IR Signal Receiver When an infrared remote control operating signal has been transmitted, the signal receiver on the indoor unit will respond as below to conÀ rm acceptance of the signal transmission. ON to OFF 1 Long Beep OFF to ON 2 Short Beep Pump down / Cool force on...
  • Página 17: Operating Range

    OPERATING RANGE Model: ATXN25/35LV1B ARXN25/35LV1B COOLING HEATING 14 15 19 20 INDOOR TEMP (ÝCWB) INDOOR TEMP (ÝCDB) DB: Dry bulb WB: Wet bulb Model: ATXN50/60LV1B ARXN50/60LV1B COOLING HEATING 14 15 19 20 INDOOR TEMP (ÝCWB) INDOOR TEMP (ÝCDB) DB: Dry bulb WB: Wet bulb 1-15...
  • Página 18: Air Filter

    AIR FILTER Open the front panel. Clean or replace each filter. • Hold the panel at the recesses on the main unit See figure. (2 recesses on right and left sides) and lift it until it • When shaking off remaining water, do not wring the stops.
  • Página 19: Service And Maintenance

    SERVICE AND MAINTENANCE Service Parts Maintenance Procedures Period Indoor air filter Remove any dust adhering to the filter by using a vacuum cleaner or At least once every wash in lukewarm water (below 40°C/104°F) with a neutral cleaning 2 weeks. detergent.
  • Página 20 ! CAUTION • Don’t touch the metal parts of the indoor unit. It may cause an injury. • When removing or attaching the front panel, support the panel securely with hand to prevent it from falling. • For cleaning, do not use hot water above 40°C, benzine, gasoline, thinner, nor other volatile oils, polishing compound, scrubbing brushes, nor other hand stuff.
  • Página 21 MEMO / LE MÉMO / MITTEILUNG / PROMEMORIA / EL MEMORÁNDUM / ПАМЯТКА / NOT...
  • Página 22 CE - DECLARA IE-DE-CONFORMITATE CE - UYUMLULUK-BİLDİRİSİ Daikin Europe N.V. 01 D declares under its sole responsibility that the air conditioning models to which this declar ation relates: 09 X заявляет, исключительно под свою ответственность, что модели кондиционеров воздуха, к которым относится настоящее заявление: 17 P deklaruje na własną...
  • Página 23 02 ** Daikin Europe N.V. hat die Berechtigung die Technische Konstruktionsakte zusammenzustellen. 08 ** A Daikin Europe N.V. está autorizada a compilar a documentação técnica de fabrico. 14 ** Společnost Daikin Europe N.V. má oprávnění ke kompilaci souboru technické konstrukce.
  • Página 24 02 ** Daikin Europe N.V. hat die Berechtigung die Technische Konstruktionsakte zusammenzustellen. 08 ** A Daikin Europe N.V. está autorizada a compilar a documentação técnica de fabrico. 14 ** Společnost Daikin Europe N.V. má oprávnění ke kompilaci souboru technické konstrukce.
  • Página 25 Kita-ku, Osaka, 530-8323 Japan Tokyo offi ce: JR Shinagawa East Bldg., 2-18-1, Konan, P.O.Box 18674, Galleries 4, 11th Floor, Minato-ku, Tokyo, 108-0075 Japan Downtown Jebel Ali, Dubai, UAE. http://www.daikin.com/global/ Importer for Turkey Hürriyet Mahallesi Yakacık D-100 Kuzey Yanyol Caddesi No:49/1-2 Kartal − İstanbul...