Mounting Installation Plate
Ensure that the wall is strong enough to withstand the weight
of the unit. Otherwise, it is necessary to reinforce the wall
with plates, beams or pillars.
Use the level gauge for horizontal mounting, and fix it with 5
suitable screws for ATXN25/35LV1B and 7 suitable screws
for ATXN50/60LV1B.
In case the rear piping draws out, drill a hole 65mm in
diameter with a cone drill, slightly lower on the outside wall
(see figure).
ATXN25/35LV1B
Mounting plate fixing screw
ATXN50/60LV1B
Mounting plate
fixing screw
Recommended Mounting Plate Retention Spots And
Dimensions
ATXN25/35LV1B
© Recommended mounting plate retention
spots (5 spots in all)
166
54.5
153.8
263
51.9
800
Liquid pipe end
ATXN50/60LV1B
© Recommended mounting plate retention spots
(7 spots in all)
190
Liquid pipe end
Gas pipe end
45
91
45
580
1065
Mounting plate
Mounting plate
Use tape measure as shown.
Position the end of a tape measure at f
184
Through the wall
hole Ø 65mm
181.7
55.5
Drain hose
position
Gas pipe end
All dimensions are in mm
173
Through
the wall
hole Ø
65mm
Drain hose
219
48
position
All dimensions are in mm
Hole with cone drill
Inside
Wall embedded pipe
(Field supply)
Wall hole cover
(Field supply)
Mount The Unit Onto The Installation Plate
Hook the indoor unit onto the upper portion of the installation
plate (Engage the two hooks at the rear top of the indoor unit
with the upper edge of the installation plate). Ensure that the
hooks are properly seated on the installation plate by moving
it to the left and right.
How To Attach The Indoor Unit
Hook the claws of the bottom frame to the mounting plate.
How To Remove The Indoor Unit
Push up the marked area (at the lower part of the front
grille) to release the claws.
Front grille
Hand indoor unit's hook here.
When stripping the ends
of interconnecting wires in
advance, bind right ends of
wires with insulating tape.
Wire guide
Water Drainage Piping
The indoor drain pipe must be in a downward gradient for
smooth drainage. Avoid situations that are likely to cause
water to leak.
Water Drainage
Water
Water
leaking
leaking
Correct
Wrong
! CAUTION
• Do not install the unit at altitude over 2000m for
both indoor & outdoor.
1-9
Outside
Caulking
Ø 65
Wall embedded pipe
(Field supply)
Mounting plate
Clip
Bottom frame
Mark (Rear side)
Mounting plate
Interconnecting
wires
Water
retention
End
dipped
Water
into
leaking
water
Wrong
Wrong
Drain