schmalz SCTSi Instrucciones De Funcionamiento página 54

Terminal compacto
Tabla de contenido

Publicidad

Funciones de los componentes
Estado
00 (verde)
01 (amarillo)
10 (naranja)
11 (rojo)
   Estado del sistema ampliado (0x008A) (Extended Device Status)
Categoría del código de evento presente y el código de evento mismo momentáneamente presente
(Event code).
Extended Device Status Event Category
Parámetro
138 (0x008A)
Description
Extended Device Status - Event Category
Byte
1+2: Event Category of current device status
Access
read only
Value range
0x10: Device is operation properly
0x21: Warning, low
0x22: Warning, high
0x41: Critical condition, low
0x42: Critical condition, high
0x81: Defect/fault, low
0x82: Defect/fault, high
Extended Device Status – Event code
Parámetro
138 (0x008A)
Descrip-
Extended Device Status – Event code
tion
Byte
3+4: Event Category of current device status
Datatyp
uint16
Length
2 Byte
Access
read only
Value ran-
Eventcode
ge
0x5100
0x5110
0x5112
0x1812
0x1802
0x1811
0x1000
0x8C01
0x180C
0x180D
0x180E
0x8C20...8C2F
0x8D00...8D0F
0x8D10...8D1F
54 / 98
Descripción
El sistema funciona sin fallos y sus parámetros operativos son óptimos
Los eyectores funcionan pero es necesario un mantenimiento
El Terminal compacto SCTSi funciona pero hay avisos presentes
Fallo – el funcionamiento seguro del Terminal compacto SCTSi dentro de los lími-
tes de funcionamiento no está garantizado (código de fallo presente en el pará-
metro Error)
Eventname
Primary supply voltage (US) too low
Primary supply voltage (US) too high
Secondary supply voltage (UA) too low
Secondary supply voltage (UA) too high
Input pressure too high (>6,3 bar) or too low
(<1, 9bar)
Internal error, user data corrupted
Internal error, Bus fault
Manual mode is active in at least one ejector
Condition Monitoring: primary supply voltage
US outside of operating range
Condition Monitoring: secondary supply volta-
ge outside of operating range
Condition Monitoring: supply pressure outside
of operating range (3,5 ... 5 bar)
Calibration fail, Ejector #1...#16
Measurement range overrun, Ejector #1...#16
Valve protection active, Ejector #1...#16
Status Category
Critical condition, high
Critical condition, high
Critical condition, high
Critical condition, high
Critical condition, high
Defect/fault, high
Defect/fault, high
Warning, low
Warning, high
Warning, high
Warning, high
Defect/fault, low
Defect/fault, low
Warning, high
ES · 30.30.01.02237 · 00 · 04/20