PROGRAMMING :
SEL key: selects the type of function to be stored, selection is
indicated by a flashing LED.
Repeatedly press the key to select the desired function. The
selection remains active for 10 seconds, (indicated by the
flashing LED); after 10 seconds, the control unit returns to its
original status.
The SET key: this programs the information according to the
type of function previously selected with the SEL button.
IMPORTANT: The function of the SET key can be replaced with
the radio control, if programmed previously (CODE led on).
MAIN MENU
The control unit is supplied by the manufacturer with the
possibility of selecting a number of important functions.
---------------------- MAIN MENU -----------------
Led Reference Led off Led On
1) CODE
No code
2) LAMP/CORT.
Flashing
3) T. MOT.
Motor time 30 sec.
4) T. PAUSA
No auto close
1) CODE: (Programming the Radio controls)
The control unit can store up to 120 different Radio Controls.
Programming the radio control with 1 or 2 Keys.
The radio control transmission codes are programmed as
follows: press the SEL key, the CODE LED will start flashing, at
the same time send the first radio control code ("Up" associated
to the Opening direction); now the CODE LED will start flashing
rapidly, send the second code ("Down" associated to the
Closing direction) to be stored, the CODE LED will remain on
and programming will be complete. If the second code is not
sent within 10 seconds the control unit will exit the programming
phase and select the function with only one key of the radio
control.
Programming the "BeFree Series" radio control with 3
Keys.
The control unit can store the whole "BeFree" radio control by
programming only the UP Key.
The "BeFree" radio control codes are programmed as follows:
press the SEL key, the CODE LED will start flashing, at the
same time press the UP key of the desired radio control; the
CODE LED will remain on and programming will be complete.
All the stored devices are deleted as
Deletion:
follows: press the SEL key, the CODE LED will start flashing,
then press the SET key for a few seconds, the CODE LED will
turn off and the codes are deleted.
Device already stored or not compatible warning:
The control unit can store up to 120 devices with different
codes. If the user attempts to perform the programming
procedure for a device which is already stored in the memory or
which is not compatible, the CODE LED will start flashing
rapidly for a few moments to indicate that this procedure cannot
be performed. The unit then returns to the programming phase
once again.
Maximum number of devices that can be stored:
The control unit can store up to 120 devices with different
codes. If the maximum number of devices has been reached
and a programming process started, the control unit will indicate
that it has failed by flashing all the LEDs except the CODE LED
which will remain lit and steady. After 10 seconds the control
unit exits programming mode.
Code entered
Courtesy Light
Programmed time
With auto close
2) LAMP/CORT. : (Selection of the flashing light or the courtesy
light)
The control unit has a 230 Vac output, for connection to a
flashing light or a courtesy light.
The control unit is supplied by the manufacturer with the
Flashing function enabled. If you wish to enable the flashing
beacon function, including during pauses, proceed as follows:
using the SEL key to move to the LAMP/CORT flashing LED
then press the SET key, and the LAMP/CORT flashing LED will
switch on steady.
Repeat the operation if you wish to restore the factory setting.
If you wish to enable the courtesy light, repeat the operation
described above, pressing the SEL button twice instead of once
(making the LAMP/CORT LED flash rapidly). Repeat the
operation if you wish to restore the factory setting.
3) T. MOT: (Programming the motor operating time max. 4
minutes)
The control unit is supplied by the manufacturer with a working
time motor predefined equal to 30 sec.
If the motor operating time has to be reprogrammed, it must be
carried out when the gate is closed, as follows: use the SEL key
to move to the flashing T.MOT LED,
the SET key. The frame will start moving up. When you have
reached the required height, release the SET key and at the
same time the motor time storage will be completed and the T.
MOT. LED will remain lit and steady. If you want an infinite
motor time, use the SEL key to navigate to the T.MOT LED
when flashing and press the SET key for less than 1 second. At
the same time the LED will turn off and the operation will be
completed. It is advisable to store a time that is a few seconds
longer after the frame has reached the end.
During programming the radio control key of the control unit can
be used instead of the SET key, if stored previously.
4) T. PAUSA:
(Automatic closing time programming max. 4 minutes)
The control unit is supplied by the manufacturer without
automatic closing. If you wish to enable automatic closing,
proceed as follows: using the SEL key to move to the flashing
T. PAUSA LED, press the SET key briefly, then wait for the
amount of time you wish to set for automatic closing; briefly
press the SET key again, and in that moment the automatic
closing time will be memorised and the T. PAUSA LED will stay
on steady. If you wish to restore the initial condition (without
automatic closing), move to the flashing T. PAUSA LED, then
press the SET key twice within 2 seconds. The LED will
switches off and the operation is complete.
When programming, you can use the radio control key on the
control unit instead of the SET key, if stored previously.

EXTENDED MENU 1

The control unit is supplied by the manufacturer with the option
of selecting only the functions listed in the main menu.
If you wish to enable the functions described in extended menu
1, proceed as follows: press and hold the SET key for 5
seconds, after which the T. MOT. and T. PAUSA LEDs will start
flashing alternately. The user then has 30 seconds to select the
functions for extended menu 1 using the SEL and SET keys.
After another 30 seconds the control unit will go back to the
main menu.
--------------------- EXTENDED MENU 1 -----------------
Reference LED
LED Off
A) CODE
remote PGM = OFF
B) LAMP/CORT
Step-by-Step
C) T. MOT.
D) T. PAUSA.
A) CODE
( Remote programming of radio control ):
7
then continuously press
LED On
remote PGM = ON
Automatic
Alternate ON/OFF flashing light
Alternate ON/OFF flashing light
rev. 3.0 13/06/2016