Check The Drainage - Electrolux EXI09HD1W Manual De Instalación

Ocultar thumbs Ver también para EXI09HD1W:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

caution
prepare the wiring as follows:
The screws which fasten the wiring to
the terminal block may come loose from
vibrations during transportation.
Check and make sure all screws are well
of the wires.
Ensure the starting voltage is maintained
at over 90% of the rated voltage marked
on the nameplate.
Always install a Residual Current Device
(RCD) in wet or moist area.
The following may be caused by voltage
drop: Vibration of a contactor, which will
damage the contact point, fuse blowing,
disturbance of the normal function of the
overload.
The means for disconnection from a
power supply shall be incorporated in the
separation of at least 3mm in each active
(phase) conductor.
Step 10: Checking the Drainage
A.
Open and lift the indoor unit front panel.
Hold the lower part of the left and right sides
of the panel, pull it against you and lift it stops
with a full support from the bracket.
Panel
bracket
20
B. Check the drainage
Carefully pour a glass of water on the
evaporator.
hose of the indoor unit without any leakage
C. Dain piping
The drain hose should
point downward for
Do not place drain piping as indicated below:
Accumulated
Do not rise
drain water
Air
Water
Water
leakage
leakage
Drain hose
Downward
slope
Tip of drain
hose dipped
Space less
in water
than 50mm
Water
Ditch
leakage

Publicidad