Disassembly
Turn "OFF" hot and cold water supplies, then
rotate handle fully counterclockwise to relieve
pressure. Remove handle parts.
1. Take out handle screw, remove handle and
washer.
2. Remove temperature limit stop, key stop and
stop tube. Lift out retainer clip. Rotate cartridge
shell between the eleven and one o'clock
positions, grasp the cartridge stem with pliers
and pull out cartridge.
Reassembly
Orient cartridge, see illustration on previous page,
then re-insert cartridge by pushing it into the body
until the cartridge ears are flush and aligned with
the top and bottom of the valve body. Replace the
retainer clip with the legs straddling the cartridge
ears. Slide down into the bottom slot.
prevents rotation and locks the cartridge into the
body. Reinstall stop tube and parts. Limit stop
must be installed with offset at TOP (12 o'clock)
position for maximum hot water. The notched flat
on the stem must point DOWN when mounting the
handle.
TEMPERATURE
KEY STOP
LIMIT STOP
To Adjust Temperature Limit
Stops
CAUTION: Due to season temperature change of
the cold water supply, the temperature limit must
be readjusted accordingly to maintain the desired
maximum discharge temperature.
1. Rotate the handle fully counterclockwise to stop
and let water run till cold water is purged, check
temperature.
2. Rotate handle fully clockwise to off, remove
handle
parts
(see
Disassembly)
temperature limit stop, rotate clockwise to
decrease and counterclockwise to increase
maximum hot water temperature, reinstall
temperature limit stop and handle (TIP: Do not
screw handle in until desired maximum
temperature is achieved)
3. Repeat
temperature is achieved.
SHOWERHEAD
TEMPERATURE
LIMIT STOP
This
ESCUTCHEON
SCREWS (2)
ROTATE LIMIT
STOP CLOCKWISE
TO REDUCE
FULL HOT POSITION
Trim
MAKE SURE ALL WATER SUPPLIES ARE OFF
TO INSTALL TRIM AFTER ROUGH-IN
1. Slide the flange into the long end of the shower
arm, wrap both ends of the shower arm with
teflon tape and screw long end into pipe ell
inside the wall. Do not install shower head at
this time.
2. Install tub spout (see spout installation
instructions).
and
3. Remove screw holding plaster ground and
stop tube guard in place and discard.
Temporarily install handle.
divert water to tub spout and flush the shower
HELPLINE: Call our toll free Helpline number,
for answers to any product, installation, replacement parts, or warranty questions.
steps
until
desired
maximum
SHOWER ARM
NOTCH
CC
CONNECTIONS
ESCUTCHEON
SPOUT
PIPE ELL
Turn water on,
1 800 289-6636
riser for 15 seconds. Install shower head and
check for leaks. If there are no leaks, turn off
and remove handle and limit stop
4. Install escutcheon plate with 2 screws
provided. Mount with the escutcheon notch up.
5. Install
temperature
limit
Temperature Limit Stop section) ensure that
notched flat on the cartridge stem points
DOWN.
Handle Attachment :
For handle style A & B : Mount handle on stem
and replace handle screw tightly. Snap handle
insert or plug button in place.
To Eliminate Cross-Piping On Back-
To-Back Installations, or To Correct
Reversed Rough-In Where Hot and
Cold Positions Are Reversed:
Remove cartridge assembly, rotate 180° and re-
install. (See Reassembly) Caution: Make sure
notch on stem is point up.
stops