Replacement Battery Cartridge
Español
Congratulations! Your new long-lasting, high-performance Replacement Battery Cartridge (R.B.C.), properly selected, is designed to extend the life
of your UPS system. All R.B.C.s are valve-regulated and employ spill-proof construction. No special handling is required. R.B.C. cases (constructed
of either ABS plastic, styrene or polypropylene) are non-conductive and have a high resistance to shock, vibration, chemicals and heat. State-of-
the-art design techniques and high quality plate production processes used to construct your R.B.C. provide a battery with an extremely high energy
density and a superior power-to-volume and power-to-weight ratio. All R.B.C.s are certified to provide:
• Compatibility with properly selected UPS systems
• Completely maintenance-free operation
• Rugged construction for long service life
Important Safety Instructions
SAVE THESE INSTRUCTIONS.
Read before attempting battery replacement! This manual contains important instructions and warnings that should be followed during the installation
and operation of all Tripp Lite Replacement Battery Cartridges (R.B.C.s).
• Follow the original UPS system manufacturer's instructions and safety information thoroughly before attempting replacement.
• To eliminate high voltage shock hazard, be sure the UPS system is turned off and the power cord is unplugged from the AC outlet prior to battery
replacement. Some manufacturers permit "hot swap" battery replacement while the UPS system is powered. Consult your UPS system's owner's
manual for guidance.
• Do not dispose of batteries in a fire; they may explode.
• Do not open or mutilate the battery. Chemicals released are harmful to the skin or eyes and may be toxic. Follow first-aid procedures for chemical
burns in the event of exposure. Use appropriate protective clothing when handling a leaking battery.
• Batteries can present a risk of electrical shock and burn from high short-circuit current. Observe proper precautions. Do not dispose of the batteries
in a fire. Do not open the UPS or batteries. Do not short or bridge the battery terminals with any object. Unplug and turn off the UPS before
performing battery replacement. Use tools with insulated handles. There are no user-serviceable parts inside the UPS. Battery replacement should
be performed only by authorized service personnel using the same number and type of batteries (Sealed Lead-Acid). The batteries are recyclable.
Refer to your local codes for disposal requirements or visit www.tripplite.com/UPSbatteryrecycling for recycling information. Tripp Lite offers a
complete line of UPS System Replacement Battery Cartridges (R.B.C.).Visit Tripp Lite on the Web at www.tripplite.com/support/battery/index.
cfm to locate the specific replacement battery for your UPS.
• Use of this equipment in life support applications where failure of this equipment can reasonably be expected to cause the failure of the life support
equipment or to significantly affect its safety or effectiveness is not recommended. Do not use this equipment in the presence of a flammable
anesthetic mixture with air, oxygen or nitrous oxide.
Owner's Manual
(R.B.C.)
Model: RBC5-192
3
1111 W. 35th Street, Chicago, IL 60609 USA
www.tripplite.com/support
Copyright © 2009 Tripp Lite. All rights reserved.
Français
• High discharge rate with deep discharge recovery
• Wide operating temperature range