Inverter/Charger
Invert:
Charge:
Reliable Emergency Backup Power
Congratulations on your purchase of the PowerVerter
gives you a convenient, reliable source of AC electricity anywhere and anytime you need it. It keeps
connected equipment up and productive through all utility power problems (blackouts, brownouts and
high voltages) by inverting DC power from user-supplied batteries into AC power. When utility power
is present, the APS700HF automatically passes through power to your equipment while simultaneously
recharging your connected battery bank. Built-in surge suppression provides connected equipment with
additional protection. The APS700HF is the clean, quiet emergency backup power alternative to gas
generators—with no fuel, fumes, or noise to deal with!
Better for Your Equipment
Better for Your Batteries
Better for You
Specifications/Warranty
Safety
Feature Identification
Operation
Battery Selection
6/2/2006
1:53 PM
Owner's Manual
PowerVerter
DC-to-AC
Model: APS700HF
Input
Output
12 VDC
120V, 60 Hz. AC
120V, 60 Hz. AC
12 VDC
Contents
2 A
3 A
4 A
5-6 A
7 A
* Inverter/Chargers are moisture-resistant, not waterproof.
Copyright © 2006. All rights reserved. PowerVerter
Page 1
®
1111 W. 35th Street, Chicago, IL 60609 USA
Customer Support: (773) 869-1234
®
APS700HF Inverter/Charger! The APS700HF
Premium Protection Levels
®
• Built-In Isobar
Surge Protection
• Automatic Overload Protection
Ideal Output for All Loads
• Frequency-Controlled Output
Faster Battery Recharge
• High-Amp, 3-Stage Battery Charger
Critical Battery Protection
• High-Efficiency DC-to-AC Inversion
Simple, Maintenance-Free Operation
• Multi-Function Lights & Switches
• Moisture-Resistant Construction*
Mounting
Battery Connection
AC Input/Output Connection
Service and Maintenance
Troubleshooting
Español
®
is a registered trademark of Tripp Lite.
www.tripplite.com
8 A
9 A
10 A
10 A
11 A
12 A

Publicidad

Tabla de contenido
loading

Resumen de contenidos para Tripp-Lite PowerVerter APS700HF

  • Página 1 200604211 APS700HF.qxd 6/2/2006 1:53 PM Page 1 Owner’s Manual PowerVerter ® DC-to-AC Inverter/Charger 1111 W. 35th Street, Chicago, IL 60609 USA Model: APS700HF Customer Support: (773) 869-1234 Input Output www.tripplite.com Invert: 12 VDC 120V, 60 Hz. AC Charge: 120V, 60 Hz. AC 12 VDC Reliable Emergency Backup Power ®...
  • Página 2: 12 Vdc

    200604211 APS700HF.qxd 6/2/2006 1:53 PM Page 2 Specifications Model: APS700HF AC Input Connection: Input Cord (NEMA 5-15P) AC Output Connection: 1 x NEMA 5-15R Battery Connection: Hardwire Inverter Continuous Power (@ 20° C) 700W/700VA DC Input Volts (Nominal) 12 VDC DC Input Voltage Range 10-15 VDC Minimum DC Fuse Rating...
  • Página 3: Important Safety Instructions

    200604211 APS700HF.qxd 6/2/2006 1:53 PM Page 3 Important Safety Instructions SAVE THESE INSTRUCTIONS! This manual contains important instructions and warnings that should be followed during the installation, operation and storage of all Tripp Lite Inverter/Chargers. Location Warnings • Install your Inverter/Charger (whether for a stationary or mobile application) in a location or compartment that minimizes exposure to heat, dust, direct sunlight and moisture.
  • Página 4: Feature Identification

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 4 Feature Identification Identify the premium features on your specific model and quickly locate instructions on how to maximize their use. Operating Mode Switch: controls AC Receptacle: Permits connection of Inverter/Charger operation. When this equipment that would normally be plugged switch is set to AUTO, connected equipment into a utility outlet.
  • Página 5: Indicator Lights

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 5 Operation Switch Modes After configuring, mounting and connecting your Inverter/Charger, you are able to operate it by switching between the following operating modes as appropriate to your situation: AUTO: Switch to this mode when you need constant, uninterrupted AC power for connected appliances and equipment.
  • Página 6 200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 6 Operation (continued) BATTERY Indicator Lights: These three lights will illuminate in several sequences to show the approximate charge level of your connected battery bank and alert you to two fault conditions: Approximate Battery Charge Level* Indicator Illuminated Battery Capacity (Charging/Discharging)
  • Página 7: Battery Selection

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 7 Battery Selection Match Battery Amp-Hour Capacity to Your Application Select a battery or system of batteries that will provide your Inverter/Charger with proper DC voltage and an adequate amp-hour capacity to power your application. Even though Tripp Lite Inverter/Chargers are highly efficient at DC-to-AC inversion, their rated output capacities are limited by the total amp- hour capacity of connected batteries plus the output of an alternator when one is used.
  • Página 8 200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 8 Mounting WARNING! Mount your Inverter/Charger BEFORE DC battery and AC power connection. Failure to follow these instructions may lead to personal injury and/or damage to the Inverter/Charger and connected systems. Tripp Lite recommends that you permanently mount your Inverter/Charger in the configuration illustrated below.
  • Página 9: Battery Connection

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 9 Battery Connection Connect your Inverter/Charger to your batteries using the following procedures: • Connect DC Wiring: Though your Inverter/Charger is a high-efficiency converter of electricity, its rated output capacity is limited by the length and gauge of the cabling running from the battery to the unit.
  • Página 10 200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 10 AC Input/Output Connection To avoid overloading your Inverter/Charger, be sure to match the power requirements of the equipment you plan to run at any one time (add their total watts) with the output wattage capacity of your Inverter/Charger (see Specifications section).
  • Página 11 200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 11 Troubleshooting Try these remedies for common Inverter/Charger problems before calling for assistance. Call Tripp Lite Customer Service at (773) 869-1234 before returning your unit for service. Battery Indicator Lights Operating Mode Switch Operation Indicator Lights SYMPTOM PROBLEMS CORRECTIONS...
  • Página 12: Tabla De Contenido

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 12 Manual del Propietario PowerVerter ® Corriente directa (DC) a Corriente alterna (AC) Inversor/Cargador 1111 W. 35th Street, Chicago, IL 60609 USA Soporte al cliente: (773) 869-1234 Modelo: APS700HF www.tripplite.com Entrada Salida Inversión: 12 VDC 120V, 60 Hz.
  • Página 13: Especificaciones

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 13 Especificaciones Modelo: APS700HF Conexión de entrada de CA: Cordón de alimentación (NEMA 5-15P) Conexión de salida de CA: 1 x NEMA 5-15R Conexión de batería: Cableado Inversor Energía continua (a 20º C): 700W/700VA Voltios CC de entrada (Nominal): 12 VCC Rango de voltaje de CC de entrada:...
  • Página 14: Garantía Limitada

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 14 Garantía limitada Tripp Lite garantiza que su inversor/cargador está libre de defectos en materiales y mano de obra por un período de un año (excepto fuera de EE.UU., Canadá y México-120 días) desde la fecha de compra por parte del usuario final. Bajo esta garantía, la obligación de Tripp Lite está...
  • Página 15: Instrucciones De Seguridad Importantes

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 15 Instrucciones de seguridad importantes ¡GUARDE ESTAS INSTRUCCIONES! Este manual contiene instrucciones y advertencias importantes que deben seguirse durante la instalación, operación y almacenamiento de todos los inversores/cargadores de Tripp Lite. Advertencias de ubicación •...
  • Página 16: Identificación De Funciones

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 16 Identificación de funciones Identifica las funciones Superior en su modelo específico y ubica rápidamente las instrucciones para optimizar su utilización. siempre dejará pasar corriente AC al equipo Conmutador para el modo de operación: Controla la operación Inversor/Cargador conectado está...
  • Página 17: Operación

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 17 Operación Modos de conmutación Después de configurar, montar y conectar su Inversor/Cargador, ya puede operarlo alternando entre los siguientes modos de operación hasta llegar al el apropiado para usted: AUTO: Cambie a esta modalidad cuando necesite energía AC constante es ininterrumpida para los electrodomésticos conectados al circuito.
  • Página 18: Restableciendo Su Inversor/Cargador Para Restablecer La Energía De Corriente Alterna

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 18 Operación (continued) Luces Indicadoras de la BATERÍAS: Esas tres luces alumbrarán en varias secuencias para indicar el nivel aproximado de carga del conjunto de baterías conectadas y alertarle de dos condiciones de fallas. Nivel aproximado de carga de batería* Indicador iluminado Capacidad de...
  • Página 19: Selección De Batería

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 19 Selección de batería Haga coincidir la capacidad en amperios-hora de su batería con su aplicación Seleccione una batería o sistema de baterías que le proporcionarán a su inversor/cargador un voltaje de corriente continua adecuado y una capacidad en amperios-hora apropiada a la potencia de su aplicación. Aun cuando los inversores/cargadores de Tripp Lite son muy eficientes en la inversión de corriente continua a corriente alterna, sus capacidades de salida están limitadas por la capacidad total en amperios-hora de las baterías conectadas, más la salida de un alternador si es que se utiliza.
  • Página 20: Montaje

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 20 Montaje ¡ADVERTENCIA! Monte su inversor/cargador ANTES de conectar la batería de corriente continua y la energía de corriente alterna. No seguir estas instrucciones puede producir lesiones personales y/o daños al inversor/cargador y a los sistemas conectados. Tripp Lite recomienda el montaje permanente de su inversor/cargador en cualquiera de las configuraciones ilustradas abajo.
  • Página 21: Conexión De La Batería

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 21 Conexión de batería Conecte su inversor/cargador a sus baterías usando los siguientes procedimientos: • Conexión del cableado de corriente continua: Aunque su inversor/ cargador es un convertidor de electricidad de alta eficiencia, su capacidad de salida está limitada por la longitud y calibre del cableado desde la batería hasta la unidad.
  • Página 22: Conexión De Entrada/Salida De Corriente Alterna

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 22 Conexión de entrada/salida de corriente alterna Para evitar sobrecargar su inversor/cargador, asegúrese de cumplir los requisitos de potencia del equipo que planea operar en cualquier momento a la vez (sume sus potencias totales) con la capacidad de potencia de salida del modelo de su inversor/cargador (vea la sección Especificaciones) Cuando estime los requisitos de potencia de su equipo, no confunda potencia “permanente”...
  • Página 23: Solución De Problemas

    200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 23 Solución de problemas Pruebe estas soluciones para problemas comunes del inversor/cargador antes de llamar para ayuda técnica. Llame a Servicio al cliente de Tripp Lite, al (773) 869-1234 antes de enviar su unidad para servicio.
  • Página 24 200604211 APS700HF.qxd 6/2/2006 1:54 PM Page 24 1111 W. 35th Street, Chicago, IL 60609 USA Customer Support: (773) 869-1234 www.tripplite.com 200604211 93-2524...

Tabla de contenido