Installation; Pump Installation - Pentair Flotec E50W220 Manual De Instalación Y Operación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

INSTALLATION

Specifications
Power supply ........................115 V, 60 Hz, 15 Amp Circuit
Liquid Temp. Range ......................32°F to 70°F (0°-21°C)
Individual Branch Circuit Required (min.) .......... 15 Amps
Discharge:.......................................... 1-1/2" Female NPT
NOTICE: This sump pump is designed for use in clear,
non-potable water. It should not be used with waterfall
or fountain pumps, applications using salt or brine
water or swimming pool drainers. Any of those uses
will void the warranty.

PUMP INSTALLATION

Tools Required:
Pipe wrench
Strap Wrench or Slip-Joint Pliers
Hacksaw
Screw Driver
File or Sandpaper
Materials Required:
1-1/2" ABS or PVC pipe with cement to match
Threaded adapter (pipe to pump)
Check Valve: Purchase either a FP0026-10
(goes in the discharge line) or FP0026-6D (goes
in the pump discharge).
Diaphragm Switch
with Tethered Switch
13" Min. with
Vertical Switch
18" Min. with
Tethered Switch
15" Min. with
Diaphragm Switch
Figure 1
INSTALLATION
1.
Construct sump pit of tile, concrete, steel
or plastic and to code requirements. Do not
construct pit of clay, earth, sand or gravel as it
will clog pump. Keep pump inlet screen clear.
• Minimum sump size:
— 10" (254mm) diameter by 10" (254mm)
depth for vertical switch models
— 14" (356mm) diameter by 18"
(457mm) depth for tethered switch
models.
4
6201 0410
2.
3.
4.
5.
10" Minimum
with Vertical and
6.
14" Minimum
Sump Pit
Hard Surface –
No Sand, Clay,
Gravel
4824 1216
7.
Finish installing the necessary plumbing. Follow
the glue manufacturer's instructions for safety
precautions and curing time.
Figure 2
Install the discharge pipe into the pump using
only PTFE pipe thread sealant and tighten to
hand-tight plus 1-1/2 turns.
nstall a check valve in the vertical pipe to
prevent backwards flow into pump. The check
valve should be installed as close to the pump
as possible along the discharge pipe.
To prevent the pump from air-locking, drill
a 1/8" (3.2 mm) hole in the discharge pipe
between the check valve and the pump.
Additionally, be sure the anti-airlock hole is
below the waterline.
To reduce noise and vibration, cut the
discharge pipe near the pump and fasten to
it a short length of radiator-type rubber hose
roughly 1-7/8' (48mm) into it with hose clamps.
Place the pump in the sump, making sure that
nothing interferes with switch operation. For
tethered switch models, the tether length
should be 3-1/2" (Figure 3).
Tether Length
6201 0410
Figure 3
6202 0410
FP877 (02-04-20)
INSTA
is st
mov
inter
from
8.
Conn
60 H
shou
and
with
into
end
burn
elec
a pro
wire
FP877 (02-

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

E50tltE50vltE75vlt