Operations
Performance (CFM) Conversion
Press and hold the High and Boost button on the hood for 3 seconds to convert blower performance.
Normal mode:
Power mode:
CAUTION
Do not activate this function without a qualified person. We recommend that a qualified technician install the
range hood. It is the installer responsibility to ensure the range hood complies with the installation clearances
specified for the product. To activate Power mode of this function, the Makeup Air system is required.
Makeup Air
When using ventilation systems with greater than specified CFM of air movement, review local building
codes as they may require makeup air systems. Consult an HVAC professional for specific requirements for
your areas as CFM requirements may vary between locals.
Consult an HVAC professional to select the correct CFM capacity range hood for your application. The CFM
capacity depends on the range or cooktop BTU rating, size and location, size of the kitchen, and the range
hood ductwork in the kitchen.

Care and Maintenance

WARNING
To avoid risk of fire and explosion do not use flammable liquids or solvents. Always plug or disconnect the
appliance from the power supply before servicing or cleaning.
Do not use steam cleaners to clean the appliance. Hidden surfaces may have sharp edges. Use caution when
reaching behind or under the appliance.
WARNING
RISK OF BURNS
The appliance will become hot when in use, especially in the area surrounding the bulbs. Let cool before clea-
ning.
WARNING

RISK OF ELECTRIC SHOCK

Moisture can cause electric shock. Only clean appliance with a damp cloth. Prior to cleaning, pull the plug or flip
the breaker in the fuse box.
Cleaning Agents
To prevent various surfaces from becoming damaged due to incorrect cleaning agents follow the specifications
given. Do not use:
Cleaning agents that are harsh or scouring
Cleaning agents with high alcohol content
Hard scouring pads or sponges
High pressure or steam cleaners
Thoroughly rinse all new sponges before use.
12
ENGLISH
appears in the display. The blower will operate normally (Max 390 CFM).
appears in the display. The blower will operate powerfully (Max 600 CFM).