Reader Tamper
If the backplate is pulled away from the wall, the tamper plate remains attached to the wall
and a wall tamper condition is generated. Likewise, if the reader is removed from the backplate,
a case tamper condition is generated.
The voltage on the Tamper line is normally low. If case tamper or wall tamper is detected, the
voltage on the Tamper line becomes high and the reader sounds 3 long beeps every 5 seconds
for two minutes, then stops.
To clear a wall tamper condition, reattach the backplate to the tamper plate. To clear a case
tamper condition, reattach the reader to the backplate.
Usage
LEDs
Red
Green
Default
Access permitted
Sounder
The reader sounds 4 rapid beeps when it is powered up or restarted.
If specified, the reader beeps once when a token is presented.

Cable Lengths

PAC door controllers only
Cable Gauge
7/0.2 0.34mm² 22AWG
16/0.2 0.5mm² 20AWG
32/0.2 1.0mm² 18AWG
Red / Green
Access denied
Distance from Reader to Controller
AC 2100 / 2200
750' / 250m
1500' / 500m
3000' / 1000m
12
Yellow
Not used
AC 202 / 512
230' / 70m *
230' / 70m *
230' / 70m *