Troubleshooting; Disposal; Spare Parts; Accessories - Honeywell KaltecSoft KS10S Instrucciones De Instalación

Ocultar thumbs Ver también para KaltecSoft KS10S:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

13. Troubleshooting

Problem
No water supply to the device
Device does not regenerate
Nothing is displayed
Incorrect time is displayed
Insufficient function
*
CS = Customer services tel. 0 18 01 - 46 63 88

14. Disposal

• High quality synthetic material housing
• All components subject to pressure in glass-fibre-
reinforced plastics
• All components to brine in Noryl
Observe the local requirements regarding
correct waste recycling/disposal!

15. Spare Parts

No. Description
1 Disinfection unit
2 Controller head seal kit
3 Spare part kit for brine pump
4 O-ring set
5 Turbine water counter
Honeywell GmbH
GB
Cause
Shut-off device in the bypass is not
open or only partially open
Pipework of the drinking water supply
is calcified or blocked
Flow meter is defective
Internal electric cabling is defective
Wrong connection of connecting hoses Connect the flexible connection lines
Rotary disc valve defective
Power supply has been interrupted
Rotary disc valve defective
Power failure occurred
Device not deaerated
Storage tank is almost or completely
empty
Blending has been set incorrectly
Control valve is contaminated or
defective

16. Accessories

Part No.
DE10S-A
EK10S-A
OFV10S-A Bypass valve insert
EK10S-B
EK10S-C
EK10S-D
13
Remedy
Open shut off valve fully
Clean or replace the pipework
Check and, if necessary, replace the
flow meter (CS*)
Check internal electric cabling (CS*)
correctly
Call Technical Customer Service
Check power suppy (mains plug, fuse)
Call Technical Customer Service
Set the time
Deaerate device
Check salt level
Check blending valve and mixing ratio
Call Technical Customer Service
D06F
Pressure reducing valve
Noise protected pressure reducing valve
with setting scale. Maximum inlet pressure
16 bar, with brass filter bowl 25 bar, outlet
pressure range 1.5 - 6.0 bar
A = With clear filter bowl up to 40 °C / 16 bar
B = With brass filter bowl up to 70 °C / 25 bar
F76S
Fine filter, reverse rinsable
AA = With clear filter bowl
AAM= With red bronze filter bowl
if a pressure scourer is applicated it is
neccessary to fit a bypass valve insert into
the bypass valve.
MU1H-1417GE23 R0110