PROBLEM – Wall Control Flashes "Service"
An operational fault has been
1.
detected
PROBLEM – Inadequate Cooling
Pump not working correctly
1.
Dry pads.
2.
Leaking ducts
3.
Weatherseal failing to open.
4.
PROBLEM – Unpleasant Odour
Odour from new pads.
1.
If your wall control display flashes "Service" or should you consider that your air cooler
requires service, you should contact your local Dealer.
When you contact your Dealer regarding service or warranty please quote the cooler
model number and serial number as shown below.
Model No.
_________________ Serial No. _____________________
®
CAUSE
CAUSE
CAUSE
TROUBLESHOOTING GUIDE
ACTION
Ensure the water supply has been turned on.
Check the cooler drain pipe is not blocked.
Turn off the Wall Control and record the
number displayed on the screen. Quote this
ACTION
Check plug, wiring and circuit breaker.
Impellor may be jammed or obstructed.
Check salinity sensor correctly installed Rectify
fault or replace pump.
Check water flow to pads.
Inspect fitment of distributor cap.
Check for blocked or kinked hose. If blocked,
dismantle, clean and flush or unkink the hose.
Find leaks and seal.
Break off transport clips.Check for
weatherseal/transition screw interference.
Check minimum fan speed setting
ACTION
Allow time to condition by running the air
cooler