Press the SET key to display its value.
Use arrow up or down to change its value.
The offset can be adjusted to +/‐ 12ºC
Press SET to store the new value.
Press SET + arrow up or wait 15 seconds without pressing any key. The new value will now be stored.
For more detailed information about programming the Dixell controllers please consult the attached
manual.
16. Trouble shooting
The appliance is not operating. Please check the following before calling for service:
Is the electrical plug connected to the mains (wall socket)? Is the fuse blown?
The appliance is operating continuously.
Please check: Is ambient temperature too high? Has the appliance recently been loaded with a large
of warm products?
The temperature inside the appliance is too high. Please check: Is the Dixell controller set to the
correct temperature? Has an excess amount of ice formed inside the appliance?
If you have checked the above points and the appliance is still not working as expected, please
contact your local dealer for further advice.
IMPORTANT NOTE!!!
Do not attempt to drill or in other way make access to the freezers interior other places than at the
marking, there is a risk of damaging the freezers tubing system, resulting in a leakage with
inflammable gasses.
17. Technical specifications
Supply voltage
Power
Intensity
Gas
Temperature range
Ambient operating temperature
Time keeping temperature below ‐20ºC
Interior volume
External dimensions (WxDxH)
Key lock
Digital controller
Acoustic alarm
Net/gross weight
*Outside this ambient temperature range, the performance of the equipment will be altered.
According to the characteristics plate
210W
4 A
R404A 130g
‐10ºC to ‐45ºC
+10ºC to +30ºC *
More than 19h
110L
725 x 655 x 865 mm
Yes
Yes
Yes
62/65 kg