Prepare the Cutout
● Always remember what kind of venting method you
desired, choosing the correct method to install. Refer
above part of Venting Method to know the detail.
Cutout for Rear Venting
1. Mark centerline of the range hood on the rear wall, which
should be matched with that of the cooktop.
2. Mark and cut out a through-hole on the wall for damper.
Refer to the dimensions outlined in Fig. 2.
3. Mark and cut out a through-hole minimum Diameter
13/8" (30mm) under the bottom of the cabinet for power
cord, refer to the dimensions outlined in Fig. 2.
Rear Cutout
Fig. 2
Cutout for Top Venting
1. Mark centerline of the range hood on the bottom of
the cabinet, which should be matched with that of the
cooktop.
2. Mark and cut out a through-hole minimum Diameter
13/8" (30mm) under the bottom of the cabinet according to
the dimensions outlined in Fig. 3.
Top Cutout
Fig. 3
Electrical
WARNING
ELECTRIC SHOCK HAZARD
● Plug into a grounded 3-prong outlet.
● Do not remove grounding prong.
● Do not use an adapter.
● Failure to follow these instructions can result in
fire, electric shock or even death.
● IMPORTANT: Observe all govering codes and
ordinances.
● Ensure that the electrical installation is adequate and in
conformance with National Electrical Code, ANSI/NFPA
70 (lastest edition), or CSA Standards C22.1-94, Canadian
6
5⅝"
(143mm)
Rear Wall
Min. 1⅜"
(35mm)
18 ⁄ "
(480mm)
23⅜" (595mm)
Bottom View of Cabinet
3¼" (83mm) 3½" (90mm)
3 ⁄ " (100mm)
10" (254mm)
23⅜" (595mm)
Center of
Range Hood
Rear View of Cabinet
5⅝"
(143mm)
3½"
Rear Wall
(90mm)
3¼" (83mm)
Min. 1⅜"
13¼"
(35mm)
(336mm)
10" (254mm)
18 ⁄ "
Center of
Range Hood
(480mm)
23⅜" (595mm)
Rear View of Cabinet
Requirements
Electrical Code, Part 1 and C22.2 No. 0-M91 (lastest
edition) and local codes and ordinances.
● Wire sizes and connections must confirm with the rating
of the appliance as specified on the model/serial/rating
plate. The model/serial/rating plate is located inside the
range hood. Wire sizes must confirm to the requirements
of the National Electrical Code, ANSI/NFPA 70 (lastest
edition), or CSA Standards C22.1-94, Canadian Electrical
Code, Part 1 and C22.2 No. 0-M91 (lastest edition) and
local codes and ordinances.
● A 120-volt, 60 Hz., AC-only, 15-amp, fused electrical circuit
is required.
● If the house has aluminum wiring, follow the procedure
below:
− Connect the aluminum wiring using special connectors
and/or tools designed and UL listed for joining copper
to aluminum.
− Follow the electrical connector manufacturer's
recommended procedure. Aluminum/copper
connection must conform with local codes and industry
Range Hood
accepted wiring practices.
Outline
● A copy of the above code standards can be obtained
from:
National Fire Protection Association
Range Hood
1 Batterymarch Park
Outline
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575Wall
● Maximum Recommended Length= 4ft (1.2m) (Fig. 4)
Fig. 4
Range Hood
Outline

Prepare the Range Hood

Prepare the Hood
NOTE: On stainless steel hoods, carefully remove all foam
packaging and the plastic protective film from all exterior
surfaces of the hood and decorative flues, prior to final
installation. Following below instruction to prepare the hood
the Top Venting or Rear Venting.
Top Venting using rectangular damper
1. Use pliers to find the seam from the edge of the top
opening and press in by left and right.(Fig. 5)
Fig. 5