Speedaire Operating Instructions
Speedaire
troubleshooting Chart (Continued)
E
N
Symptom
G
L
Fluid leaking from fluid
I
tip of pressure feed spray
S
gun
H
Excessive overspray
Will not spray
Manufactured for Dayton Electric Mfg. Co.
Niles, Illinois 60714-4014 U.S.A.
Gravity Feed Spray Gun
®
Possible Cause(s)
1. Packing nut too tight
2. Fluid tip worn or damaged
3. Foreign matter on tip
4. Fluid needle spring broken
1. Too high atomization pressure
2. Too far from work surface
3. Improper stroking (arcing, gun motion too
fast
1. No pressure at gun
2. Fluid control not open enough
3. Fluid too heavy
Corrective Action
1. Adjust
2. Replace tip and/or needle
3. Clean
4. Replace
1. Reduce pressure
2. Adjust to proper distance
3. Move at moderate pace, parallel to surface
1. Check air lines
2. Open fluid control
3. Thin fluid or change to pressure feed system
8
4XP65B