Helios 3
4 Light - 240 volt Lighting Controller
Easy Guide
VANCOUVER, W ASHINGTON U.S.A.
Instructions for Use
1. Please consult with a licensed electrician prior to installa-
tion of the Helios 3. High voltage can be dangerous!
2. Connect 240 volt power to the 3 screws under the pro-
tective cover. (See 'Instructions for Operation' section).
3. Replace protective cover with screws provided.
4. Securely mount your Helios 3, with hardware provided,
near the ballasts to be operated. It should be placed
away from water, mist, spray, etc.
5. Plug your ballasts into the outlets on the left and right
TM
side of the controller.
6. Set the time to current time of day.
7. Turn on Helios 3 power switch to activate lighting
controller.
8. Your Helios 3 will now control your ballasts at the
desired settings until the power is defeated.
Controller Specifi cations
Controlling a light bank
Sun System
Sun System
Wiring
diagram
R
to 240 Volt Ballast
Helios 3
240 Volt
to 240 Volt Ballast
R
to 30 Amp Power Source
Ground
Hot
Neutral
Hot
Size: 11"H x 11"W x 4"D
Weight: 4 lbs.
Voltage Input: 240 volts
Voltage Output: 240 volts
Maximum Amperage: 30 amps
Maximum Wattage: 4000 Watts
Hertz: 60 Hz
Time switch: 24 Hours with 15 minute increments
Operating Temperature: 40o to 125o F | 5o to 52o C
Storage Temperature: 32o to 135o F | 0o to 57o C
to 120 Volt
Timed Outlet
Fan
to 240 Volt Ballast
to 240 Volt Ballast
www.titancontrols.net
For technical assistance call us at
1-888-80-Titan or 1-888-808-4826.
Sun System
R
Sun System
R
®