REPLACING THE MAIN BURNER NOZZLE AND
ADJUSTING THE PRIMARY AIR FLOW.
Remove the control panel.
Loosen the screws V1.
Remove the nozzle-support manifold.
Slacken screw V.
Remove nozzle UM and replace it with the one indicated
in table T1.
Retighten nozzle UM.
Adjust air regulator Z to distance A as shown in table T1.
Retighten screw V fully.
Re-assemble all parts. For assembly, proceed in reverse
order.
26
Instructions for installation

REPLACING THE PILOT BURNER NOZZLE

Remove the control panel.
Undo connector R.
Remove nozzle UP and replace it with the one indicated
in table T1.
Retighten the connector R. Re-assemble all parts.
For assembly, proceed in reverse order.

13. COMMISSIONING

See Chapter " INSTRUCTIONS FOR MAINTENANCE".