CONTROL LEVER
The control lever (H106) can be set in three
positions (see below).
LOWER
NEUTRAL
ASCENT
ZEROING THE DISPLAY
You can press the ZERO key at any time to zero
the scale. This will usually only be necessary
when the pallet is empty. When the zero point
is obtained the display will show zero.
The scale has an automatic rezeroing function
to account for minor drifting or accumulation
of material on the pallet. However, you may
need to press the ZERO key to rezero the
scale if small amounts of weight are shown
when the pallet is empty.
TARING
Zero the scale by pressing the ZERO key if
necessary. The zero indicator will be on.
Place a container on the pallet, display
shows weight.
Press the TARE key to tare the scale. The weight
that was displayed is stored as the tare value
and that value is subtracted from the display.
Zero shows on display. The "GROSS" indicator
will be off and "NET" indicator on. As product
is added, only the weight of the product will
be shown. The scale could be tared a second
time if another type of product was to be
added to the first one. Again only the weight
that is added after taring will be displayed.
When the container is removed a negative value
will be shown. If the scale was tared just before
11 OF 62

OPERATION

LOWER:
Push lever up to lower
the forks
NEUTRAL
NEUTRAL:
to move the load
ASCENT
ASCENT:
Push lever down and
pump handle to raise
the forks.
removing the container this value is the gross
weight of the container plus all product that was
removed. The zero indicator will be on because
the pallet is back to the same condition it was
when the ZERO key was last pressed. Press TARE
key again to escape "NET" mode.
WEIGHING
Put the control lever in the LOWER position
and lower the truck to lowest position.
Press the ON/OFF key to turn the scale on. After
ASCENT
the indicator counts down, the display will
zero. Place the forks under the pallet. While
balancing load as evenly as possible, put
lever in "Ascent" position and pump handle
to raise load. Once stable indicator shows,
the accurate weight of the load is displayed.
(Total weight of pallet and the goods)
NET/GROSS FUNCTION
This function is only available after TARE
function has been used. Pressing the N/G
button will toggle between total weight
(gross) on skid and weight after TARE function
was used (NET).
SELECTING WEIGHING UNITS
Press U key to select desired weighing units
(LBS or KG).
ACCUMULATION
NOTE: Before using Accumulation
function, remove all weight from
forks and zero the scale.
1. Weigh item on scale. Once "stable"
indicator shows, press M+ key to store
weight in memory.
2. The display will show "AC 01" and then
the total in memory for 2 seconds before
returning to normal.
3. The M+ indicator is on. Remove the
weight, allow the scale to return to zero,
and put a second weight on the scale.
4. Press M+ key, the display shows "AC 02"
and then the new total.
5. Continue until all weights have been
added. The scale can accumulate up to
99 items.
NOTE: Changing weighing units
during Accumulation Function will
clear memory.
0721 IH-4564