Infiniton GG-319 Manual De Instrucciones página 12

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TABLE2:
How to Convert Gas Source
Adjustment of the reduced valve flow
Burners
Flame
Full flame
Regular burners
Saving flame
Valve adjustment
Valve adjustment should be done with the control knob set at Burner ON saving flame position.
Remove the knob, and adjust the flame with a tiny screwdriver (see fig.7 below).
To check the adjusted flame: heat the burner at full open position for 10 minutes. Then turn the knob into the
saving setting. The flame should not extinguish nor move to the nozzle. If it extinguish or moves to the
nozzle, readjust the valves.
Flame selection
As the burners are adjusted correctly, the flame should be light blue, and the inner flame should be clear.
The size of flame depends on the position of the related control knob.
-Burner ON, large flame
See fig.8 for various operating options (flame size selection); the burner should be set at a large flame
during the initial phase of cooking, it make food boil quickly. Then should turn knob to the saving flame
Converting the
hob from LPG
to natural gas
Replace the burner
Nozzle according
To the guidelines in
table 1
Loosen the adjustment
Spindle (see fig.7 below )
And adjust the flame
Fig.7
-Burner ON, small flame(saving mode)
Fig.8
Converting the
hob from natural gas
Gas to LPG
Replace the burner
Nozzle according
to the guidelines in
table 1
Loosen the adjustment
Spindle (see fig.7 below )
And adjust the flame
12
-Burner OFF