Infiniton GG-319 Manual De Instrucciones página 9

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

f) In the event the gas hob is not installed on a built-in oven, a wooden panel must be inserted for insulation.
This panel must be placed at least 20 mm distance from the bottom of hob.
lmportant: When installing the hob on a built-in oven, the oven should be placed on two wooden strips; in
the case of a joining cabinet surface, remember to leave a space of 45 x 560 mm at least from the back
side..
When install hob on a built-in oven without forced ventilation, ensure that have air inlets and outlets to
ventilate the interior of the cabinet adequately.
Gas connection for gas hob
The gas hob should be connected to the gas-supply by a registered installer. During installation it is
essential to fit an approved gas tap to isolate the supply from the hob for the convenience of any
subsequent removal or servicing. Connect the hob to the gas mains or liquid gas, it must be carried out
according to the prescribed regulation in force, and only after it is ascertained that it is adaptable to the type
of gas to be used. If not, follow the instructions indicated in the paragraph headed "Adaptation to different
gas types". In the case of connection to liquid gas by tank, use pressure regulators that conform to the
regulation in force.
Important: For safety, for the correct regulation of gas use and long life of the hob, ensure that the gas
pressure conforms to the indications given in table 1 "Burners and Nozzle Specifications".
Connection to non-flexible tube
(copper or steel)
Connection to the gas source must be done in such a way as to not create any stress points at any part of
the gas hob.
The hob is fitted with an adjustable "L" shape connector and a gasket to the gas supply.
The connector should be dismounted and the gasket must be replaced.
The feeding connector of the gas to the hob is threaded 1/2 gas cylinder.
Connection to flexible steel tube
The gas feed connector to the hob is threaded, 1/2" connector for round gas pipe. Only use pipes and
sealing gaskets that conform to the standards currently in force. The maximum length of the flexible pipes
must not exceed 2000 mm. Once the connection has been made, ensure that the flexible metal tube does
not touch any moving parts and not be crushed.
9

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Gg-320

Tabla de contenido