7 .
Check to ensure the driver assembly is plumb. If not,
remove base driver assembly, making the appropriate
adjustments to the hex nuts in order to provide a level
base.
8.
Once driver assembly is plumb, add one (1) washer,
and one (1) nut per anchor bolt. Torque bolts to 30 ft.-
lbs. (41 N-M).
9.
Make all electrical connections, referring to the wiring
diagram.
1.
Supply side ground wire to green luminaire lead.
2.
Supply side neutral wire to white luminaire lead.
3.
Supply side line voltage wire to black luminaire
lead.
10. Locate 2 pin polarized connector and ground wire
on driver assembly. Lift bottom (open end) of bollard
housing and position the 2 pin connector and ground
wire near the top driver assembly. Assemble connector
and connect ground wires.
11. Place bollard housing over base driver assembly,
aligning bottom holes with base extrusion.
CAUTION: Ensure the LED and ground wires do not
get pinched between base driver assembly and fixture
housing.
Installation Instructions – 6 in. Round Bollard, BRT6
12. Use the four (4) ¼" socket cap flat head screws to
fasten the bollard housing to the base. Tighten to 30
in-lbs. (3.4 N-M). (Figure 4)
Figure 4.