AXIS P12 Network Camera Series
3
Digital input
4
Digital
output
Power Connector
2-pin terminal block for DC power input. Use a Safety Extra Low Voltage
(SELV) compliant limited power source (LPS) with either a rated output
power limited to ≤100 W or a rated output current limited to ≤5 A.
Connect to pin 1 to activate, or leave floating
(unconnected) to deactivate
Connected to pin 1 when activated, floating
(unconnected) when deactivated. If used
with an inductive load, e.g. a relay, a diode
must be connected in parallel with the load,
for protection against voltage transients.
18
0 to max 40 V DC
0 to max 40 V DC, open
drain, 100 mA