5. Check that the indicator LEDs indicate the correct conditions. See for further details.
Note that some LEDs can be disabled and may be unlit.
Shorten Sensor Unit Cable
The sensor unit is delivered with a cable. Note that this cable cannot be extended. To shorten
the cable follow these steps:
1. Cut the cable to the desired length. Measure from the sensor unit.
2. Strip the plastic outer coating from the end of the cable.
3. Peel back the shield.
4. Flatten the colored wires in the order described below.
1
Brown
2
White/brown
3
Not used
4
Not used
5
White/blue
6
Blue
NO TICE
TICE
NO
NO
TICE
Make sure that the wires stay in the correct order and that the cable shield makes good
contact with the connector shield.
5. Insert the wires all the way into a shielded 6P6C RJ12 connector.
6. Use a crimping tool to fasten the connector to the cable.