Installation Manual of Room Air Conditioner
Preparation
Necessary Tools for Installation
Hammer
●
Nipper
●
Hacksaw
●
Hole core drill
●
Spanner(17,19 and 26mm)
●
Gas leakage detector or
●
soap-and-water solution
Power Source
●
Before inserting power plug into receptacle, check the voltage without fail.
The power source is the same as the
●
Install an exclusive branch circuit of the power.
●
A receptacle shall be set up in a distance where the power cable can be
reached.Do not extend the cable by cutting it.
Drawing for the installation of indoor and outdoor units
The models adopt HC FC free refrigerant R410A
more than 10cm
(3 7/8)
more than 10cm
(3 7/8)
Arrangement of piping
directions
Rear left
Rear
Left
right
Right
Below
The marks from
to
A
in the gure are the
G
parts numbers.
The distance between
the indoor unit and the
oor should be more
than 2m.
more than 60cm
Please be subject to the actual product purchased , the above picture is just for your reference.
Read this manual before installation
Explain suf ciently the operating means to the user according to this manual.
NO.0010536243
Torque wrench
●
(17mm,22mm,26mm)
Pipe cutter
●
Flaring tool
●
Knife
●
Measuring tape
●
Reamer
●
corresponding name plate.
more than 15cm
more than 20cm
(7 7/8)
(23 5/8)
Selection of Installation Place
Indoor Unit - Select a plocation that is
●
Robust not causing vibration, where the body can be supported sufficiently.
●
Not affected by heat or steam generated in the vicinity, where inlet and outlet of the
unit are not disturbed.
●
Possible to drain easily, where piping can be connected with the outdoor unit.
Where cold air can be spread in a room evenly.
●
●
Nearby a power receptacle. (Refer to drawings).
●
Place where the distance of more than lm from televisions, radios, wireless apparatuses
and fluorescent lamps can be left.
●
In the case of fixing the remote controller on a wall, place where the indoor unit can
receive signals when the fluorescent
Outdoor Unit - Select a plocation that is
●
Not less affected by rain or direct sunlight and is sufficiently ventilated.
●
Strong enough to bear the unit, where vibration and noise are not increased.
●
Place, where discharged wind and noise do not cause a nuisance to the neighbors.
●
Place, where a distance marked
Attention must be paid to
the pitch of drain hose
more than 10cm
(3 7/8)
A
C
(5 7/8)
more than 25cm
(9 7/8)
lamps in the room are in use.
is available as illustrated in the above figure.
Optional parts for piping
Non-adhesive tape
A
Adhesive tape
B
Saddle (L.S) with screws
C
Connecting electric cable
D
for indoor and outdoor
E
Drain hose
F
Heating insulating material
Piping hole cover
G
Floor xing dimensions of the
outdoor unit (Unit:mm / inch)
For:HSU18VCK-W
113.5
633
113.5
(4 1/2)
(24 7/8)
(4 1/2)
For:
HSU24VCK-W
184
184
580
(7 1/4)
(7 1/4)
(22 7/8)
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts (10mm) and nuts rmly
and horizontally.
When tting the unit to wall
surface, roof or rooftop, x
a supporter surely with nails
or wires in consideration of
earthquake and strong wind.
If vibration may affect the
house, x the unit by attaching a
vibration-proof mat.