ID=1 (both main and secondary) or ID=3.
During auto-on, the audio line (if the user has entered a conversation) and the door opener service will also be
available on the selected door unit.
The function works with both main and secondary video door units except in the case of the main door
unit with ID=0, on which it is essential for each user to activate auto-on.
So in this case the parameter will not be visible on the SETTINGS
The described filter only works when the function is activated on the installed door units. When it is not
programmed, the odd and even user codes are not differentiated. For example, with function active
on main door unit 1 (odd) and deactivated on main door unit 3 (also odd), the user with ID 16 (even)
will not be able to use the auto-on function on main door unit 1 but will be able to do so on main door
unit 3.
USER INTERFACE DISPLAY LANGUAGE
This parameter allows you to choose the language shown on the display of the button panel. The following
languages can be selected:
•
Italiano (default)
•
English
•
Français
•
Español
•
Deutsch
•
Nederlands
•
Polski
•
Norsk
•
Português
•
Vlaams
•
Slovenščina
•
čeština
ENABLE/DISABLE VOICE FEEDBACK
This parameter enables or disables the voice messages played by the control button panel. Voice messages and
the respective enabling or disabling parameter are only available for the following languages:
•
Italiano
•
English
•
Français
•
Español
•
Deutsch
•
Nederlands
With the parameter disabled or not available, beeps will be heard as acoustic feedback as an alternative
to voice messages.
PASSWORD
This parameter can be used to set the password (4 digits) for setting up the device as a WiFi access point to
access configuration.
DOOR UNIT TYPE: SECONDARY
If "SECONDARY" value is selected in the DOOR UNIT TYPE parameter, the two new parameters described below
will be present on the SETTINGS
SECONDARY DOOR UNIT COLUMN ADDRESS
If the door unit is secondary, its RESPECTIVE COLUMN ADDRESS must have a value between "0" and "31", and
must coincide with the column ID set on the column interface (Ref. 1083/50) which powers it.
SECONDARY DOOR UNIT ADDRESS
In the same column there may be two secondary door units which must have different PE addresses [or door unit
ID]; the values which may be assumed are "0" or "1".
DS1784-003
web page:
screen.
23