DMX Linking

The Kinta HP can work with a DMX controller. Instructions for connecting and configuring this product for DMX operation are
in the User Manual. If you are not familiar with DMX, download the DMX Primer from www.chauvetdj.com.
Starting Address
To ensure full access to all channels available in each DMX mode, the highest recommended DMX address is 501.
Master/Slave Connection
The Kinta HP uses the DMX data connection for its Master/Slave mode. Information about configuring the Kinta HP for
Master/Slave operation is in the User Manual, which is available from the Chauvet website.
IRC-6 (Infrared Remote Control)
The Kinta HP can be operated with the CHAUVET IRC-6. For more information about the IRC-6, download instructions
for the IRC-6 or the Kinta HP User Manual from www.chauvetdj.com.

DMX Values

12CH
Channel
Function
1
Auto program
Program speed
(when Ch. 1 is 001  250)
2
Sound sensitivity
(when Ch. 1 is 251  255)
3
Red
4
Green
5
Blue
6
White
7
Cyan
8
Magenta
9
Yellow
10
Orange
11
Strobe
12
Motor rotation
3CH
Channel
Function
1
Auto program
Program speed
(when Ch. 1 is 001  250)
2
Sound sensitivity
(when Ch. 1 is 251  255)
3
Motor rotation
3
QUICK REFERENCE GUIDE
Value
Percent/Setting
000  250 Automatic program
251  255 Sound-active mode
000  255 Program speed, slow to fast
000  255 Sound sensitivity, low to high
000  255 0–100%
000  255 0–100%
000  255 0–100%
000  255 0–100%
000  255 0–100%
000  255 0–100%
000  255 0–100%
000  255 0–100%
000  005 No function
006  255 Strobe, slow to fast
000  255 Motor speed, slow to fast
Value
Percent/Setting
000  250 Automatic program
251  255 Sound-active mode
000  255 Program speed, slow to fast
000  255 Sound sensitivity, low to high
000  255 Motor speed, slow to fast
Kinta HP QRG Rev. 1