Mount Cover Plate - Honeywell 50001137-001 Instrucciones De Instalación

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Mount Cover Plate

Mount Small or Medium Cover Plate Directly to Wall (See Fig. 2)
1. Pull the wires through the wire hole on the cover plate and wall plate.
2. Position the cover plate and wall plate on the wall with the arrows pointing up. Level the wall plate for appearance
only.
3. Use a pencil to mark the mounting holes for your thermostat.
4. Remove the cover plate and wall plate from the wall and drill two 3/16-in. holes in the wall (if drywall) as marked.
For firmer material such as plaster, drill two 7/32-in. holes. Tap the wall anchors (provided with the thermostat)
into the drilled holes until flush with the wall.
5. Pull the wires through the wire hole on the cover plate and wall plate. Position the cover plate and wall plate on
the wall anchors.
6. Insert the mounting screws (provided with the thermostat) into the wall anchors. Check leveling, if desired, and
tighten the mounting screws.
WALL OPENING
WALL ANCHORS (2)
(PROVIDED WITH
THERMOSTAT)
U P
Fig. 2. Mount cover plate, wall plate and thermostat directly to wall.
WIRE
COVER PLATE
WIRE HOLE
MOUNTING HOLES (2)
3
50001137-001 COVER PLATE ASSEMBLY
WALL PLATE
WIRE HOLE
MOUNTING HOLES (2)
MOUNTING SCREWS (2)
(PROVIDED WITH
THERMOSTAT)
THERMOSTAT
M22394