Before Requesting Repairs or Service
WARNING
This product can be disassembled and repaired by qualified repair technicians only.
If you find any problems, follow the troubleshooting procedures below.
Problem
The power does
not turn on.
No or very little
mist is produced.
The Power/Water
indicator stays lit
red even when
water is supplied.
An odor is emitted.
The mist seems like
it stops every 20
seconds.
Primary Cause
The power cord is not
plugged into the outlet.
The Power/Water
indicator (P/E) light is red.
The ceramic disc must be
replaced.
* The ceramic disc has an
expected service life of
about 3,000 hours.
The water tank is
not mounted to the
humidifier securely.
Using water other than
clean water.
This is not a malfunction.
To prevent water from
accumulating at the
mist outlet, the fan
motor cycles on for at
least 2 seconds every
20 seconds.
13
Soluition
Plug the power cord into the outlet.
Fill with water.
* Even if you press the Power button
immediately after the Power/
Water indicator turns off, the
humidifier does not produce mist
for about 2 minutes. This is because
the water temperature is heated to
at least 140°F for sterilization before
starting the misting operation.
If the service life of the ceramic disc
is exceeded, the amount of mist
generated can drop or fail to be
generated at all. When the ceramic
disc needs to be replaced, contact the
service center (a charge applies for
replacing it).
Load the water tank so that it fits
properly.
Drain the water left in the water tank
and clean by following the procedure in
"Cleaning and Storage".
This is normal operation, and it is not a
malfunction.