Case 5:
1 zone via radio and siren via radio to TM600P
wired base unit, connection with Xr20
Radio control and wired SK50 to base unit.
PROGRAMMING
System code
!
Enter the XR100 system code as indicated in section 3. This is also used for the XR152, XR200, XR20, XR300 and
XR100 (Slave), which should interact with the base unit.
Function code
!
The function code for this installation is:
OPERATING IN MASTER MODE
Green LED:
Off
On
Flashing light
Red LED:
On
Flashing
Flashing light
Buzzer:
Sounds continuously for 3 seconds Base unit disconnection
3 beep
2 beep
3 beep
4 beep
10 beep
25 beep about
Intermittent
When an alarm is sent from an XR200 contact or XR152 infrared sensor, the relay contacts open for that zone. If
the sensor receiver alarms are active (11-bit to ONE) and the base unit is disconnected, the XR300 sirens will sound for 5
minutes. Otherwise, the XR100 will wait for the base unit to set off the alarm by sending a positive signal to input B to activate
the internal buzzer (if not disabled) and sirens via radio.
With the base unit disconnected, the XR100 module will signal for a zone to open by opening the relay contacts.
Any tampering of the contacts or sensors, opening the corresponding tampers, will be transmitted from the XR100 via
activation of the internal buzzer.
Any faults in the power supply to the sensors, contacts or sirens is indicated through activation of the red LED and the
internal buzzer (10 beeps), which is repeated every four hours (if not disabled through the 12-bit configuration).
Connection and disconnection of the base unit can be controlled from the XR20 radio control (in this case the XR100
module works for just one zone), also when coupled to an electronic key system (see connection diagram). The red button on
the left connects the base unit, while the green button on the right disconnects it. With the 7-bit correctly configured, you can
also use the XR20 radio control for pulse controlled base units such as the TM600, allowing you to command a full connection
using the left button and a partial connection with the right button (short and long pulses - 6 and 7-bit to ONE).
0 - 0 - 0 - 0 - 0
-
Wireless expansion interface
Zone
SK50
radio 2
1 - 1 - 0 - 0
-
0 - 0 - 0 - 0
System connected
System disconnected
24hr. tamper memory sensors and sirens
Exterior power supply fault
System alarm active
Alarm memory
Connection of base unit
Zone 2 gong (opening relay)
Zone 3 gong (opening zone 3 relay, if enabled)
Zone 4 gong (without opening relay)
Sensor and siren power failure.
Sensor and siren tamper
Alarm signal
Base unit
XR100
Master
11