security
"1" In MASTER mode, the XR100 can be used with two radio zones, sending separate alarm signals to the base unit
generated by sensors programmed into zone 2 (relay 1 output) or zone 3 (relay 2 output). In this case, the radio
control can no longer be used to connect and disconnect the base unit, and the bit 6 setting is ignored.
bit 9
Impulse controlled alarm cycle
In SLAVE mode, this setting is ignored and any wired sirens remain active until the alarm reaches the base unit, or
for up to a maximum of 5 minutes.
"0" The presence of positive voltage at input B activates the alarm signals for a maximum of 5 minutes, which are
interrupted when this voltage is removed or if the base unit is disconnected. After the 5 minutes, any remaining
positive voltage at input B will prevent the alarm cycle from restarting.
"1" An alarm cycle of 5 minutes is controlled by a positive impulse at input B, and can only be silenced by
disconnecting the base unit. At the end of an alarm cycle, any remaining positive voltage at input B prevents
another one from starting, while an impulse during the alarm phase will reset the 5-minute count to zero.
bit 10
Disabling alarm buzzer
"0" Internal buzzer enabled in alarm phase
"1" Internal buzzer disabled in alarm phase, but not in the event of a tamper alarm.
bit 11
Sensor signal alarm cycle
Function not present in SLAVE mode, setting ignored.
"0" An alarm cycle activation signal can only be sent from the base unit when connected to input B.
"1" The receipt of a signal from a sensor or a contact generates an alarm cycle, even without the presence of voltage
or an impulse at input B.
bit 12
Enabling buzzer repeat for sensor and siren power supply fault
Function not present in SLAVE mode, setting ignored.
"0" Siren power supply fault signals are sent to the buzzer at the time of the event only, with 10 beeps.
"1" Siren or sensor power supply fault signals are sent at the time of the event and are repeated every 4 hours.
bit 13
Exclusion connection/disconnection buzzer signal
"0" The buzzer signals connection with an intermittent sound and disconnection with a long tone.
"1" The base unit connection/disconnection buzzer signal is excluded.
Wireless expansion interface
15