HDFS3P1 - INSTALLATION INFORMATION FOR HUMIDITY SENSOR AND FAN CONTROL
HDFS3P1
Humidity Sensor and Fan Control
SPECIFICATIONS
Power..................................................................................................120VAC, 60Hz
Maximum fan load.......................................................................................3 Amps
Fan Time Delay.............................................................................................20 mins
Humidity range...................................................................................45%-80% RH
DIRECTIONS
The HDFS3P1 is a 3 Amp, single pole Humidity Sensor and Fan Control
Switch. This sensor helps conserve energy and automates the fan in which
it is connected, which provides energy savings and reduces the possibility
of mold and mildew. When the humidity sensor detects excess humidity in
a room, it automatically turns on the ventilation fan. The sensor continues
to monitor the air and automatically turns the fan off when the humidity
level drops below its preset level.
WARNING
Turn the POWER OFF at the circuit breaker before installing the sensor
Read and understand these instructions before installing. This device is
intended for installation in accordance with the National Electrical Code
as well as local regulations. It is recommended that a qualified electrician
performs this installation. Make sure to turn off the circuit breaker or
fuse(s) and make sure power is off before wiring the device.
Use copper wires only. NEUTRAL WIRE IS REQUIRED.
WIRING DIRECTIONS
1. Connect RED wire from sensor to the FAN wire.
2. Connect BLACK wire from sensor to the HOT wire.
3. Connect WHITE wire from sensor to the NEUTRAL wire.
4. Connect GREEN wire from sensor to the GROUND wire.
Neutral
Neutre
Neutro
Black
Noir
Negro
Line
Ligne
Línea
Green
Vert
Verde
Ground
Mise à la terre
Conexión a
tierra
Red
Rouge
Fan
Rojo
Ventilateur
Ventilador
Load
Charge
Fase
Neutral
Neutre
Neutro
White
Blanc
Blanco
OPERATING INSTRUCTIONS
The HDFS3P1 features three adjustable humidity levels for customizable
control to suit the specific ventilation needs of the room. These humidity
levels are as follows:
1. High Humidity (80% RH)
2. Medium Humidity (65% RH)
*(default)
3. Low Humidity (45% RH)
Fan Mode: Manual ON, Auto OFF
a. The manual button is used to turn the fan off after a 20 minute time delay.
b. If the fan is in the ON state, the manual button is used to turn off the
fan before the time delay expires, the fan will immediately turn off and
the humidity sensor will stop working.
c. Turn ON the manual button and the humidity sensor will be operational
after 20 minutes.
Humidity Mode: Auto ON, Auto OFF
a. The Fan will turn ON automatically when preset humidity level is
reached and automatically turn OFF when the humidity level drops below
the preset.
b. If the humidity level is higher than preset for 3 minutes, then the fan will
continue to run for 5 minutes.
c. When the manual button is used to turn OFF the fan before the 20
minutes is reached, the fan will turn OFF immediately and the humidity
sensor will stop detecting. Only when the manual button is set to ON
then the humidity sensor will resume operation after 20 minutes. Expect
a 3 minute delay for the automatic sensor to turn on the fan.
PROGRAMMING
• Function: Humidity Level
1. High Humidity
2. Medium Humidity
3. Low Humidity
STEP 1 : Enter Programming Mode
• Press and hold the fan button for eight seconds until the bi-color LED
light comes on. The sensor is now in programming mode.
STEP 2 : Choose the Setting
• Press the fan button the same number of times for that function
*default
www.eaton.com
www.eaton.com/wiringdevices
EIS-0268-EFS (REV. A)

Publicidad

loading

Resumen de contenidos para Eaton HDFS3P1

  • Página 1 Humidity range...................45%-80% RH DIRECTIONS The HDFS3P1 is a 3 Amp, single pole Humidity Sensor and Fan Control Switch. This sensor helps conserve energy and automates the fan in which it is connected, which provides energy savings and reduces the possibility of mold and mildew.
  • Página 2: Warranty Information

    Quality Control Dept., Eaton Wiring Devices, 203 Cooper Circle, Peachtree City, GA 30269; in Canada: Eaton Wiring Devices, 5925 McLaughlin Road, Mississauga, Ontario L5R 1B8. Eaton will repair or replace the defective unit, at its option. Eaton will not be responsible under this warranty if examination shows that the defective condition of the unit was caused by misuse, abuse, improper installation, alteration, improper maintenance or repair of damage in shipment to Eaton.
  • Página 3 GARANTIE LIMITÉE DE 2 ANS D’EATON WIRING DEVICES Eaton Wiring Devices garantit que Le HDFS3P1 est doté de trois niveaux de réglage de l’humidité pour un contrôle son capteur d’humidité avec commande de ventilateur est exempt de défauts de fabrication personnalisable en fonction des besoins particuliers de ventilation de la pièce.
  • Página 4: Especificaciones

    Ejemplo de programación: Para cambiar el nivel de humedad del interruptor de alto El HDFS3P1 es un sensor de humedad y control del ventilador de 1 polo a 3 Amp. a medio, siga los pasos que se muestran a continuación: Este sensor ayuda a conservar la energía y automatiza el ventilador al que está...
  • Página 5 Folding and Printing Instructions- Document Dimensions: 8.5” W x 11” H 2-sided printing, Accordian fold in fourths logo at top, fold in fourths again. Final Size: 2.25” W x 2.75” H...