urmet domus 1139/3 Manual De Instalación página 8

Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 14
WITH FLUSH-MOUNTED CASING Ø 60 MM
Install fl ush-mounting box at the height indicated.
Remove the plastic base from the door phone unit and fi x the base to the wall as shown in the drawing here
below.
n° 1 screw and screw
Connect.
Fix the door phone to its plastic base.
DISTANCES, SECTIONS CABLES AND TECH SPECS
Type of connection
Call to fl oor level
Panic Alarm
Call repeating
Yokis devices
LAN
(#) To ensure longest-range door phone operation, the cable must be a class 5e device and the twisted
pairs' cross section must be AWG24.
The maximum resistance of the individual wires must not exceed 10ohm/100m.
The cable must be up to the following standards:
- EIA/TIA 568-B.2 or EIA/TIA 568-C.2
- EN50288 3-1
- IEC 61156-5
The connection between the door phone and POE switch must be ensured by a single cable without any
extra patch cords.
POE input voltage: ......................................................................................................................... 48-54 V
Max consumption @ 48 V: ....................................................................................................................125 mA
Operating Temperature: ...................................................................................................................-5 ÷ 45°C
Maximum current X1/GT or Y1/GT contacts: .........................................................................50 mA - 12 Vdc
8
anchor included
n° 1 2,9 x 13 mm
countersunk screw
1
Max distance
30 m
30 m
30 m
10 m
100 m
Box Ø 60 mm
Min - max cross section
0,5 - 1 mm
2
0,5 - 1 mm
2
0,5 - 1 mm
2
0,5 - 1 mm
2
CAT5e (#)
DS1139-003

Publicidad

Tabla de contenido
loading

Tabla de contenido