TROUBLESHOOTING
Check the position of the Air Gap Switch before beginning troubleshooting.
Lighted switch is OFF, no load response to ON/OFF/DIM button press:
• Make certain that the circuit breaker is on and functioning.
Lighted switch is ON, no load response to ON/OFF/DIM button press:
• Check the controlled dimmable lighting load (light bulb). Make sure that the
load connected to the RD-200 is between 25- 500 watts.
• The lighting load may not appear to be ON if the last used dimming level was
very low. To verify if this is the case, fi rmly tap the ON/OFF/DIM button one
time. The amber LED should turn off. Next, press and hold the ON/OFF/DIM
button to turn UP the lighting level. If the lights do not get brighter, call
technical support.
Load will not turn ON automatically when the area is occupied and the
sensor is in Mode 2 (lighted switch is ON):
• Press the ON/OFF/DIM button. If the load turns ON, check the light level
setting and also make sure the sensor lens is not blocked. The light level can
prevent the sensor from turning on the load automatically.
• If the load does not turn ON when you press the ON/OFF/DIM button, check the
dimmable lighting load. Make sure that the load connected to the RD-200 is
between 25- 500 watts.
• The lighting load may not appear to be ON if the last used dimming level was
very low. To verify if this is the case, fi rmly tap the ON/OFF/DIM button one
time. The amber LED should turn off. Next, press and hold the ON/OFF/DIM
button to turn UP the lighting level. If the lights do not get brighter, call
technical support.
Load will not turn OFF automatically:
• Press the ON/OFF/DIM button. If the controlled load turns OFF, go to next step.
• The time delay can be set from 30 seconds to 30 minutes. Ensure that there is
no movement within the sensor's view for the set time period. Hot air currents
and heat radiant devices can cause false detection. Make sure the sensor is
at least 6 feet (2 meters) away from devices that are a signifi cant heat source
(e.g., heater, heater vent, high wattage light bulb).
If load does not respond properly after following troubleshooting, turn OFF
power to the circuit then check wire connections or call technical support.

WARRANTY INFORMATION

Watt Stopper/Legrand warranties its products to be free of defects in materials
and workmanship for a period of fi ve (5) years. There are no obligations or
liabilities on the part of Watt Stopper/Legrand for consequential damages arising
out of, or in connection with, the use or performance of this product or other
indirect damages with respect to loss of property, revenue or profi t, or cost of
removal, installation or reinstallation.